View larger
1SDA100976R1
100976
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 93d6f3fa-58f9-4037-8785-ac86d441821a Italy |
| Simplified SCIP | bb56340e-5921-454a-ab7a-a660cc521c10 Finland |
| 6df4bd2a-cfe1-4df3-9c81-14dd3b03629d Poland | |
| f3aa30f1-839d-412a-8c72-dead93abb3b5 Germany | |
| 06d1ee0e-1af9-4af0-92d6-3b38d1e61ea4 Belgium | |
| cc7058ab-551b-4879-9dd7-debfbcfb67eb Bulgaria | |
| 69571f7f-6014-497a-9cfa-64768ed943fe Poland | |
| 1ee09ff4-26af-46da-832b-301403364364 Croatia | |
| a1c05387-7440-4d81-bcbe-0b5beabf6bbb Czech Republic | |
| 1f45d9f9-e2f8-4a68-a6a7-28376453b2d6 Germany | |
| a64b4fa4-b515-4f17-a1cf-c59316297ae2 Germany | |
| a24e639a-a1af-4e20-a44d-c5161c202338 Belgium | |
| 5959a428-01f1-4d30-b4a2-ea636b224e95 Norway | |
| 14ee464d-288b-495c-bf84-028e53c7d9c2 Denmark | |
| 96bab390-2460-483c-8e8d-9e85a7da635f Greece | |
| 9527fce8-7d2a-45e1-bb5f-04e6437b5403 Estonia | |
| 91c5d401-3cc3-4479-9385-f13b463f79e3 Hungary | |
| 75c7aac8-2f5e-4515-9046-ebbd208b98a6 Sweden | |
| e7b675bf-8232-42bb-9bbb-4f902dac3764 Poland | |
| 275b1fa5-4810-4768-9c68-003b21486917 Netherlands | |
| e6dc747d-8e5e-42db-a6cb-06503bed489b Hungary | |
| 5f72ef62-ad24-4722-867d-f880bb315898 Germany | |
| 58a77cba-e79d-4363-ae81-d9c0f75086c2 Spain | |
| d746d188-9dca-41d5-8c7e-87ceef4f7f73 France | |
| 7b98e6e4-c286-443c-8659-e5fe86e04e1c Sweden | |
| 49881d31-e00a-4b8a-87e5-c342088c2f11 Germany | |
| f3379e5d-fca0-4326-8557-1508be35016c France | |
| acd9e1a7-c78f-4ef8-80e3-52eb1115544b Portugal | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7LE312ERFF000XXX |
| E-Number (Norway) | 4380701 |
| EAN | 8056221010306 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 9.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 11.2 kg |
| Package Level 1 EAN | 8056221010306 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1336 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 57 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (240 V AC) 200 kA | |
| (380 V AC) 120 kA | |
| (415 V AC) 120 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 65 kA | |
| (690 V AC) 50 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (240 V AC) 200 kA | |
| (380 V AC) 120 kA | |
| (415 V AC) 120 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 65 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Release | Ekip Touch Measuring LSI |
| Release Type | EL |
| Short-Circuit Performance Level | L |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| 1SDH001821A1001 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1250 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 1250 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 12500 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1875.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |