View larger
1SDA100871R1 ABB XT7S 1000 Ekip G Dip LS/I In1000A 3p F F
1SDA100871R1
100871
ABB
1 unit
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Abb 1SDA100871R1 is an XT7S 1000 Ekip G Dip LS/I In1000A 3p F F circuit breaker designed for robust electrical distribution networks, providing essential overload and short-circuit protection for heavy industrial equipment. Molded case circuit breakers protect downstream assets and safely interrupt fault currents to prevent costly downtime. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2357
- Environmental Product Declaration - EPD: 9AKK108468A1895
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 64.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: af4c25d8-c4b7-4313-9d0b-af07a66d90c8 China
- Simplified SCIP: 12a0161e-fb28-4374-b037-1e58d6287352 Estonia
- Ambient Air Temperature: Operation -40 ... 125 °C
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT7SE310DXFF000XXX
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | af4c25d8-c4b7-4313-9d0b-af07a66d90c8 China |
| Simplified SCIP | 12a0161e-fb28-4374-b037-1e58d6287352 Estonia |
| e004bed5-d799-45cd-8b75-c87124daec98 Belgium | |
| fa922303-cf2a-4fda-8464-460e8314b054 Germany | |
| 3d022658-b818-4dc2-9fa7-e0e7ed20f14e Hungary | |
| 156e762b-e97f-44de-a7dc-a0aa3bcec70c Croatia | |
| 7c45e852-b3e8-4e35-9002-b5dfa70e8bb7 Poland | |
| 2a7d144b-705b-480e-8c5c-a9a8953c96af Czech Republic | |
| 35053c8f-9dda-4975-bf9f-d3d20ddd6918 Poland | |
| 3b59c960-112e-40b1-af78-f522e0d69003 Netherlands | |
| fb10954a-13f0-4381-a3f0-9818b8c7f4c5 Germany | |
| af7fc0f3-8d4f-4348-82b9-85000f9227db Spain | |
| b84bd71e-8b93-4dca-9365-d6da756d290b France | |
| 4c0615d1-1ecc-469e-9fc4-d2ca06f69dcd Sweden | |
| 5641fac6-ed4a-4772-a946-097210e8d34c Belgium | |
| 47bf2317-2f96-40e8-9b63-4ad4213f9347 Germany | |
| acc4e830-64dc-473e-825b-2c3f5772ea71 France | |
| 0bdb6db2-da23-4e96-9f33-af4f5b654533 Finland | |
| 1ed04730-22a9-4b5e-bb70-632b6f24a960 Bulgaria | |
| 46e3a587-dec0-426e-b7fb-8e5f439773b4 Portugal | |
| 6867499b-8665-4780-9dd0-99a987f421b6 Hungary | |
| 21bae6d0-72ed-47de-a97f-37c8b4630301 Poland | |
| 39ee7e0e-35f0-447f-89c0-e74a47c1cb8c Sweden | |
| b7192ba7-71ca-4d51-99aa-6374b70fbd9f Germany | |
| e2c6c9ab-7753-470d-8236-a90225c6cbd5 Germany | |
| 130bf461-49e5-4ac3-b487-f689d3b19fa2 Greece | |
| b114d637-2b5d-41be-9109-af9dacb725cd Norway | |
| ce3f88eb-e522-4d79-b1f7-891632a709a7 Denmark | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7SE310DXFF000XXX |
| E-Number (Norway) | 4380628 |
| EAN | 8056221009256 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 9.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 11.2 kg |
| Package Level 1 EAN | 8056221009256 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Generator Protection |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1336 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 37 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Release | Ekip G Dip LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |