An ABB XT7S 1250 Ekip Dip LSI In 1250A 3p F F is a high-performance molded case circuit breaker designed to safeguard robust commercial and industrial power distribution architectures. These devices offer precise electronic tripping capabilities to isolate faults and protect assets. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2357
- Environmental Product Declaration - EPD: 9AKK108468A1895
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 64.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: dc2e3427-4e1e-4833-b348-27bad3cb1b6b Italy
- Simplified SCIP: e2b38ec9-925d-45d8-be6a-335b436e513c Germany
- Ambient Air Temperature: Operation -40 ... 125 °C
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT7SE312EFFF000XXX
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | dc2e3427-4e1e-4833-b348-27bad3cb1b6b Italy |
| Simplified SCIP | e2b38ec9-925d-45d8-be6a-335b436e513c Germany |
| 68f95577-5ead-4f1f-a7c1-d1978eac8fef Poland | |
| 51b833f7-b805-4f9b-89ab-6cd43b4448a7 Norway | |
| 61f57648-2021-4bf9-936f-36d9b72aad4e Finland | |
| 264b7361-bba4-4be4-b822-115b16e9b018 Netherlands | |
| 3ecadeb8-fa38-487a-b431-5512ab33a8ae Germany | |
| b134fc81-319b-4a74-afbe-852c14188f65 Denmark | |
| bee31f80-b1b0-4b3c-b7e8-44cda459407f Germany | |
| c436e49f-69ad-44d6-a37c-5938f1b5164e Croatia | |
| 118722fe-6908-4975-8ce2-4b35cc081c43 Czech Republic | |
| dc2d89a5-4fab-48e1-9721-bf10e628bab1 Poland | |
| 03f74315-c161-4ed7-ae54-7ae9edeeb118 Netherlands | |
| 280b7ac6-d9df-46eb-a2cf-b63ee21266c5 Netherlands | |
| ebac4f23-54fe-46fc-8a2b-219c61e2f781 Estonia | |
| 9d0390ba-1126-4af7-bbe1-1d60634bed5a Greece | |
| f60b12ac-fd88-4562-aac4-761c1cc732b1 Portugal | |
| 8fc9fffa-8e2b-46df-a030-b6ec8ebf1bc3 Bulgaria | |
| 02fab9e0-8394-4860-ab4e-b8c35da25b64 Sweden | |
| 0149620f-ab5d-477a-a993-d8f2b89a9959 Poland | |
| 905a8b3a-a4b4-421f-ba10-fd27ca83352f France | |
| a7d4153d-74ab-4abd-bd0e-36fe1168dc39 Sweden | |
| b015d167-45fe-49e8-8023-6de0548927cf Germany | |
| 54ed640e-e1e5-4422-bf88-15185f4f3057 Germany | |
| 182166d4-e9f4-4f96-afb2-70429ba0df55 France | |
| 06e0afd7-6a3f-489d-8369-5e65a525f7e8 Netherlands | |
| 3eab9ef5-4b1f-4a73-b834-648f47738ccb Spain | |
| 65b530e1-6059-47cc-bcdc-8dec0f95c014 Netherlands | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7SE312EFFF000XXX |
| E-Number (Norway) | 4380621 |
| EAN | 8056221008860 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 9.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 11.2 kg |
| Package Level 1 EAN | 8056221008860 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1336 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 57 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |