View larger
1SDA100826R1 ABB XT7S 800 Ekip Dip LS/I In 800A 3p F F
1SDA100826R1
100826
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb 1SDA100826R1 moulded case circuit breaker provides high-performance current interruption and system protection in demanding electrical networks. These breakers safeguard switchboards and machinery by tripping automatically during short circuits and overloads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2357
- Environmental Product Declaration - EPD: 9AKK108468A1895
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 64.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: d30d319a-05f1-4935-a37b-0816345668ac Italy
- Simplified SCIP: 673b7733-454f-4c91-a9ba-f1fdf7e1974c Germany
- Ambient Air Temperature: Operation -40 ... 125 °C
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT7SE380CEFF000XXX
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | d30d319a-05f1-4935-a37b-0816345668ac Italy |
| Simplified SCIP | 673b7733-454f-4c91-a9ba-f1fdf7e1974c Germany |
| e694ae5a-2a0e-48df-ab21-0b6d8c59a554 Spain | |
| 7e3e1041-b495-4102-8e71-f396e633ca8a Netherlands | |
| a3f9c6d7-cf32-45be-82b6-5a14b5b02c29 Norway | |
| 6d383d5b-b56a-44f4-a4b4-8318adf58fb3 Finland | |
| c52e1033-2b65-45ef-9598-81bfdee8aeb4 Poland | |
| b8ee4a8f-2ba3-407b-8af1-fe66659eda56 Netherlands | |
| b7a2a279-0091-4ca1-8f17-40a345864e89 Germany | |
| e831933a-34b5-4cbf-af21-6789ee387aeb Denmark | |
| f432b8c0-5148-43ab-a828-c93696d84739 Germany | |
| a05e7285-c426-4406-ac00-94cb5c1fbae8 Croatia | |
| 254fe977-10ff-477d-b8d9-eca627371514 Czech Republic | |
| 583c93c3-0e97-4b08-b33c-41122413cc4c Poland | |
| 77302b37-0d02-4f26-8f24-65df23a099dd Netherlands | |
| e4dca1e9-01b6-4473-9397-dfc86a444213 Netherlands | |
| 43934e96-63f9-4231-9803-a81381f2c1dc Estonia | |
| be64a5de-bc8d-4b62-bff3-457a5776a767 Greece | |
| 07ff8057-e567-4214-94aa-6bcd45225b06 Portugal | |
| 14cf4503-57c5-4e0f-843c-83f8590fae08 Bulgaria | |
| 9f140129-86cb-45e5-8f85-4c76edc49d66 Sweden | |
| 84331962-aec0-40eb-91e6-bbe3db015a2b Poland | |
| d9601985-f1c5-4036-a81e-040a98068790 France | |
| b810066f-3883-45c3-b712-cb8d7cfaf193 Sweden | |
| 45e47103-3529-4e3b-b0f9-3f7866073f76 Germany | |
| 13398e0e-fd67-4b47-95d9-33a96af8250b Germany | |
| 195a0723-3dbf-4032-a0d4-004ee4287505 France | |
| 427f3e05-3238-4158-9144-6ef5d64634c6 Netherlands | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7SE380CEFF000XXX |
| E-Number (Norway) | 4380615 |
| EAN | 8056221008808 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 9.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 11.2 kg |
| Package Level 1 EAN | 8056221008808 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1336 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 24 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip Dip LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |