Request QuoteProduct Overview
A molded case circuit breaker, identified by part number 1SDA100756R1 ABB XT6S 800 Ekip Dip LSI In 800 4p F F, offers reliable circuit protection for high-ampere electrical distribution architectures. Technicians integrate this device into switchgear systems to safely isolate faults and protect downstream assets from overcurrent damage.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2356
- Environmental Product Declaration - EPD: 9AKK108468A9752
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 60 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: ae56e95b-aa19-4435-a258-bc6ae782f206 Italy
- Simplified SCIP: 041726a1-ff6a-4fc0-9aba-5c458a27da93 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT6SE4800FFF000XXX
- E-Number (Finland): 3641886
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2356 |
| Environmental Product Declaration - EPD | 9AKK108468A9752 |
| 9AKK108468A2295 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 60 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | ae56e95b-aa19-4435-a258-bc6ae782f206 Italy |
| Simplified SCIP | 041726a1-ff6a-4fc0-9aba-5c458a27da93 Germany |
| 2a327770-45c0-488a-a320-9d14c9b37921 Belgium | |
| b375b5f6-ae8b-4c4d-98b9-f973b1a39ac6 Germany | |
| c2c9ae1f-35d3-4dad-9043-db8f0957648d Denmark | |
| 8c20f381-d6b1-4079-bb3c-92299f0dc084 Germany | |
| 33728f52-5bfb-4ee8-b62b-cdd1441dce34 Poland | |
| 9ab7fed0-022a-499d-9509-e14ef061191b Finland | |
| ed90dd83-581e-4abe-9acd-634f2e8bb7a1 Poland | |
| 64aee76f-b9b6-43c6-bfd2-7d233a438865 Czech Republic | |
| ce5e72bb-07ea-4244-8976-7efb61f25b37 Croatia | |
| c685b87a-dfd3-4ec2-b5cc-a2873beadfac Germany | |
| 2e7acc23-9fa2-4ddb-84fa-5fb9f7c8cf23 Hungary | |
| 57f7c086-cc23-4997-82f8-f46992b1ee0a France | |
| 4f8744aa-fcda-47eb-ac2e-efd48e2a577d Spain | |
| 09637b6b-07cb-48a2-9953-786f2ab104e3 Belgium | |
| 7da38f02-6293-43df-a1a9-8deac7596505 Netherlands | |
| fb0ea70b-0874-4bc4-a748-bef399b805eb Norway | |
| 92d5f6ad-5e5e-4adc-9793-e317e7f497be Hungary | |
| 4731fa92-0424-4b61-b55a-8ac8c2774ecc Estonia | |
| 97ecf5c5-878e-4f49-9613-17eaa1359308 Greece | |
| 74709321-cb73-42eb-a818-fccf87226a31 Sweden | |
| 35a2a71a-b7b1-4f16-b3d4-754903f7a851 Poland | |
| d56cc4de-7dd5-4812-84da-8e129930838c France | |
| 55582d05-b978-4db7-8ac5-1e177239d0e4 Germany | |
| 3d5a4919-ab81-4e4f-b56d-f39dad0132e7 Sweden | |
| 6242bc26-151d-47eb-a8be-62590c0a85b2 Bulgaria | |
| 18910548-bb3f-47ad-9739-52ccac6c3896 Portugal | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT6SE4800FFF000XXX |
| E-Number (Finland) | 3641886 |
| E-Number (Norway) | 4380585 |
| EAN | 8056221008105 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 12 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 14 kg |
| Package Level 1 EAN | 8056221008105 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1214 |
| 1SDH002065A1245 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | 53.4 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (525 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 10 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (525 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| (250 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 2 Poles in Series 35 kA | |
| (750 V DC) 3 Poles in Series 24 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT6 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2825 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002012A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002012A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |