View larger
1SDA100747R1 ABB XT6S 800 Ekip M Dip I In 800A 3p F F
1SDA100747R1
100747
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB molded case circuit breaker, referenced as 1SDA100747R1 ABB XT6S 800 Ekip M Dip I In 800A 3p F F, delivers specialized motor protection and short-circuit interruption for heavy industrial machinery. These devices are installed in motor control centers to safeguard high-horsepower applications.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2356
- Environmental Product Declaration - EPD: 9AKK108468A9752
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 60 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 686391ea-dc8a-44b9-a2a7-77bc4318ee80 China
- Simplified SCIP: 0ab8c559-1665-4d84-912a-2103de0cbafe Czech Republic
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT6SE3800KFF000XXX
- E-Number (Norway): 4380528
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2356 |
| Environmental Product Declaration - EPD | 9AKK108468A9752 |
| 9AKK108468A2295 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 60 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 686391ea-dc8a-44b9-a2a7-77bc4318ee80 China |
| Simplified SCIP | 0ab8c559-1665-4d84-912a-2103de0cbafe Czech Republic |
| 656793ca-dbf5-4c29-b324-0d49d092508e Finland | |
| 34f69add-d2b8-4208-947b-5717ee7b991d Hungary | |
| be9eff7d-3d18-43e8-ac10-20dfdb40efa1 France | |
| 6caf4eff-4379-41b6-b1e3-94a84b0237bb Greece | |
| 9bb44c38-ddcb-44b9-a065-122f3a389b18 Germany | |
| 49d9e328-ba84-43b1-beae-ed2519ca86cf Germany | |
| a633d9cc-f04e-4d7f-bc89-1aef5dc6b5ff Denmark | |
| 2157fff3-d329-4e8c-869f-18b72296cbb3 Spain | |
| 4f291dc8-1be9-4a0a-a73c-d51c36418738 Belgium | |
| 71c8e934-995f-4345-9129-cfbe93879cf3 Netherlands | |
| 33f1ffc5-9df5-421a-85eb-79dd084c859f Poland | |
| d493c20c-d785-452c-9c9d-382ddd74e6a7 Hungary | |
| e8004471-9d14-4fbb-8b44-c8d34a7fe829 Estonia | |
| b3212bf6-3f35-456f-aa41-3db2ebddbadc Belgium | |
| 37695309-410f-47fd-bd04-73a21c0db494 Norway | |
| 777653b9-5fa4-436e-a12e-22c3db3d9718 Sweden | |
| f69e0172-dac4-49f8-ae0c-ea764db49842 Germany | |
| 0a819da0-f146-4de0-8df2-e456a71a68de France | |
| 5ac1f6a4-4a7a-4bcd-ae95-1b0f8476b2d6 Germany | |
| babc8008-3cfa-43e6-a00a-53e68d15d298 Croatia | |
| c72cdde3-8b2f-4363-8ee3-f4a7221c3f01 Poland | |
| c928eda8-b167-4bc5-ba2e-558692e77d7c Germany | |
| 02a043cf-4876-4c7a-bfef-9eecad1eca13 Sweden | |
| 042c5cfc-d19f-4d83-b0ca-42588921525c Poland | |
| 25644f33-7ce8-41b7-b908-7a28fdbb72c7 Bulgaria | |
| 1f41de96-04bd-445e-a52a-cd46c76d06d2 Portugal | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT6SE3800KFF000XXX |
| E-Number (Norway) | 4380528 |
| EAN | 8056221003728 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 9.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 12 kg |
| Package Level 1 EAN | 8056221003728 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Motor Protection |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1190 |
| 1SDH002065A1245 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 53.4 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (525 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 10 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (525 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| (250 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 2 Poles in Series 35 kA | |
| (750 V DC) 3 Poles in Series 24 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip M Dip I |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT6 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2825 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002012A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002012A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |