View larger
1SDA100743R1
100743
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2356 |
| Environmental Product Declaration - EPD | 9AKK108468A9752 |
| 9AKK108468A2295 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 60 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 9501870a-9da7-48f4-b3dd-0995406920ff Italy |
| Simplified SCIP | c7a3c4a0-0dc4-4601-a30e-259c4d8c69e4 Belgium |
| d7dc2855-8219-454d-851b-1285ffef3138 Germany | |
| 10893c6b-f433-4ea8-a7eb-bcf2dd101f13 Denmark | |
| 8aef2b3c-1249-420e-8796-b5a785acc8f5 Germany | |
| bc18b529-b67a-45d1-b41c-42e8bcb57f25 Germany | |
| 49733c4e-fc7d-485d-ad4d-8cf315a3cee5 Poland | |
| 5acf5f95-d7eb-460d-9f84-ab529395f45f Finland | |
| 5f8662b8-0b12-4e8d-9fe5-9aa4556a6250 Czech Republic | |
| 25404193-9d1b-4160-8dd8-94e7d2996578 Poland | |
| e6f9f2e6-59bb-4a11-906f-994a9247eb25 Croatia | |
| 9a828c37-0132-4529-afc2-5ce37cea8817 Poland | |
| f0e6830e-3f55-4602-85e8-d084aa847f9c France | |
| 7a32fc7e-d478-4fde-a1e8-bce636611fc4 Greece | |
| f7d48bc6-d95f-4645-a6b1-ab379cb5744f Portugal | |
| c09b7f2d-39ff-4ed4-bcee-75d25c3abb57 Bulgaria | |
| c4901e37-d141-4ffc-9585-89eed2254cb3 Sweden | |
| c7c58cb5-ad42-4529-9d2b-3a3f69763ef1 Sweden | |
| 853e7d52-3349-4583-8d2d-c010b8c12c39 Germany | |
| bdc0c074-2c84-4090-8943-4ae37f69d191 Estonia | |
| d1b1aa3f-3d61-40c5-a357-fd4ba72e4df1 Norway | |
| 49f768d4-d6e1-4890-beba-52a964d9fad8 Netherlands | |
| 5f262ece-c80d-44a5-b972-5847a93f997f Hungary | |
| 09c1da7f-b624-4f0f-afce-dab18c03a7c6 Hungary | |
| 784b6e49-79a5-4590-9c77-9258aa659c04 Germany | |
| 08d85219-6802-464e-be8d-97a8c41a53ec France | |
| f9367148-a78b-4081-b243-cc01aba0df6d Spain | |
| ac379112-5055-4c70-b4d9-44ceed6bddea Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT6SE3800FFF000XXX |
| E-Number (Finland) | 3641885 |
| E-Number (Norway) | 4380526 |
| EAN | 8056221003681 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 9.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 11 kg |
| Package Level 1 EAN | 8056221003681 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1190 |
| 1SDH002065A1245 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 53.4 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (525 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 10 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (525 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| (250 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 2 Poles in Series 35 kA | |
| (750 V DC) 3 Poles in Series 24 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT6 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2825 |
| Mechanical Drawings | 1SDH002012A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002012A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 800 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 320.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 800 A |
| Adjustment range undelayed short-circuit release (EF007131) | 800 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |