View larger
1SDA100741R1 ABB XT6S 800 Ekip Dip LS/I In 800 3p F F
1SDA100741R1
100741
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for robust electrical protection, this Abb 1SDA100741R1 circuit breaker safeguards industrial distribution lines by interrupting excessive fault currents and overloads. Units of this type are essential for maintaining facility uptime and equipment safety. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2356
- Environmental Product Declaration - EPD: 9AKK108468A9752
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 60 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: d811a0ca-b52e-40b8-ae93-d660f613d616 Italy
- Simplified SCIP: c459b1ff-8fb1-48fa-857d-ec86c8da5622 Denmark
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT6SE3800EFF000XXX
- E-Number (Finland): 3641881
- E-Number (Norway): 4380524
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2356 |
| Environmental Product Declaration - EPD | 9AKK108468A9752 |
| 9AKK108468A2295 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 60 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | d811a0ca-b52e-40b8-ae93-d660f613d616 Italy |
| Simplified SCIP | c459b1ff-8fb1-48fa-857d-ec86c8da5622 Denmark |
| 694a85fc-7ead-4cb4-8e03-41efb4be218a Germany | |
| 78a795a0-8fdc-4f94-8d3a-f12a863169de Germany | |
| b0a2ebb9-3e57-47b7-8cd7-50eb73ba89ff Poland | |
| 2a31617a-5818-46ea-909c-ebae2ed48197 Germany | |
| c4d4c818-a25d-4aa8-ae2c-b61fd56d4cf5 Finland | |
| d1cd1e7e-0698-4cb7-aa5a-2d03cb34d5c3 Belgium | |
| a396c9d0-f3be-499d-bc08-235a6e0e9454 Czech Republic | |
| c2275b1c-56a1-4d31-8de5-385b0520ab04 Croatia | |
| e8bd0203-14bc-41a4-8ffc-5b2ef17eb5d7 Poland | |
| 59c172eb-18b2-41f9-b3ba-edb7ebf2d0c5 Germany | |
| 16f4765c-9738-433d-8dfb-58f3e6f9ab42 Sweden | |
| 5f45ba0e-bcc0-4df5-aca8-2a9e028b9ff9 France | |
| 0648de52-a65f-44e1-9571-bb8c8fa3d8c9 Portugal | |
| eb008ec7-abd3-4ed4-9d19-4d0e07323c54 Bulgaria | |
| 2df25b62-87aa-4a55-ad0c-7067fa78a079 Sweden | |
| fbcfca45-2bf1-41fa-b766-a4323b4430c7 Poland | |
| 05ca8f0e-5b06-41fe-aa97-aa8d70ad2834 Greece | |
| c634ecba-aed2-4bc6-a63f-888cd8101eab Hungary | |
| 860fa841-c13c-4480-8fc7-0b5965314a73 Germany | |
| 788aec3f-7f11-4aa7-a572-c958b6ce68d8 France | |
| 0f8c6758-79db-44b4-be5e-17d1ceb1d054 Spain | |
| 8fc2b3c3-f0fb-40bb-88d4-980fc1091f2c Belgium | |
| c09340bc-8a2b-42d6-8626-0e3bbf90add3 Netherlands | |
| d9bfd2f7-920b-4361-863f-131118b5ec0d Estonia | |
| 3b99918c-5796-4da5-b8bd-77ec0a7ff816 Hungary | |
| a6d85263-f293-4990-b82c-f3ac73221d8f Norway | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT6SE3800EFF000XXX |
| E-Number (Finland) | 3641881 |
| E-Number (Norway) | 4380524 |
| EAN | 8056221003667 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 9.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 11 kg |
| Package Level 1 EAN | 8056221003667 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1190 |
| 1SDH002065A1245 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 53.4 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (525 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 10 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 45 kA | |
| (500 V AC) 35 kA | |
| (525 V AC) 35 kA | |
| (690 V AC) 22 kA | |
| (250 V DC) 2 Poles in Series 50 kA | |
| (500 V DC) 2 Poles in Series 35 kA | |
| (750 V DC) 3 Poles in Series 24 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip Dip LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT6 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2825 |
| Mechanical Drawings | 1SDH002012A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002012A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |