View larger
1SDA100734R1 ABB XT6N 800 Ekip Dip LSI In 800 4p F F
1SDA100734R1
100734
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
1SDA100734R1 ABB XT6N 800 Ekip Dip LSI In 800 4p F F is a molded case circuit breaker designed to protect electrical circuits from overloads and short circuits in industrial environments. Such components provide reliable fault interruption to prevent equipment damage and ensure personnel safety. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2356
- Environmental Product Declaration - EPD: 9AKK108468A9752
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 60 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 1cab6e26-7e09-4555-b261-61d47c69b0ac Italy
- Simplified SCIP: efc369fb-1b48-472a-b765-42ea86905f2c Czech Republic
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT6NE4800FFF000XXX
- E-Number (Finland): 3641878
- E-Number (Norway): 4380579
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2356 |
| Environmental Product Declaration - EPD | 9AKK108468A9752 |
| 9AKK108468A2295 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 60 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 1cab6e26-7e09-4555-b261-61d47c69b0ac Italy |
| Simplified SCIP | efc369fb-1b48-472a-b765-42ea86905f2c Czech Republic |
| 25423fb6-3273-45a2-9bf9-72f8be91064f Croatia | |
| 50b900c2-98d5-4904-841f-400454b3ec5f Denmark | |
| ee69f0da-0b89-402b-98d6-0be0da4dc61a Germany | |
| 418a1ce8-7c4c-4799-b3b5-2c0707fd4396 Germany | |
| 2e98ccf1-75b3-4e52-b49c-bbcbba28ac98 Belgium | |
| 91631b4d-c758-4aad-9bf7-34ae02740790 Finland | |
| b8407d43-8129-4f00-9698-9556b93b2fb8 Poland | |
| de577373-f863-4034-987a-e2b3fc6761ed Poland | |
| 41df6345-38cd-441b-8f60-9f6dfac52e39 Germany | |
| 2f2e34c2-939d-4441-a05c-f70550d32977 Hungary | |
| 86c4cc12-5f06-4137-838e-88bf944468fd Germany | |
| 5071137e-ba98-4ef3-9cfd-7800caafe8c5 France | |
| de725ad7-0a47-42e9-8b04-b3353fb0aa7f Spain | |
| 9c22bb59-ca0a-427b-b351-15bba081866d Belgium | |
| 50c8e940-ee6d-4fa3-b59b-b1bcc8eca272 Netherlands | |
| 737f8a64-ee2a-4761-8d11-2a1cc37c5fc1 Hungary | |
| bd2597ee-ae1c-4bd1-95ca-69e7272de68a Norway | |
| 985c02ca-54b0-47f5-99b8-09e32ae8d272 Bulgaria | |
| 2d6cabc6-4b36-48f1-9709-547cd59fbfe8 Portugal | |
| f7ea8bf9-2932-4ff5-97ee-5c9760e3e0fa Greece | |
| d5a8b993-cb8b-4497-9f39-d903636a2d8c Estonia | |
| 9594abad-6552-44b3-a825-3c84b428e4ca Sweden | |
| 3002d55f-7843-4171-aae8-c9cd842a1fb8 Poland | |
| bdaac41c-a7f3-49d9-8e72-95d8ee687a0f Sweden | |
| 360a4875-8a28-4f5d-a167-29b81a1123b4 Germany | |
| 148737fd-3614-41ae-b275-e66b07585b38 France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT6NE4800FFF000XXX |
| E-Number (Finland) | 3641878 |
| E-Number (Norway) | 4380579 |
| EAN | 8056221003599 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 12 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 14 kg |
| Package Level 1 EAN | 8056221003599 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1214 |
| 1SDH002065A1245 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | 53.4 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 30 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 10 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 30 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 2 Poles in Series 20 kA | |
| (750 V DC) 3 Poles in Series 18 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT6 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2825 |
| Mechanical Drawings | 1SDH002012A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002012A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |