View larger
1SDA100725R1
100725
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2356 |
| Environmental Product Declaration - EPD | 9AKK108468A9752 |
| 9AKK108468A2295 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 60 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 04e9fd5d-e4e5-4619-acf8-bf6eb133bf48 China |
| Simplified SCIP | 3fc68e2f-b0be-4a7d-bce3-5008e12cc50c Hungary |
| 67e868f6-cac7-49f6-9fe2-30fc33b76e66 Netherlands | |
| 26c798f4-eab1-411a-9576-2478a53d7ddd Estonia | |
| 919d3835-1afa-42f5-b74e-45adf6dcd846 Sweden | |
| 1fdec102-9833-44b7-a1d5-8a8daf961c60 Poland | |
| 1195e55a-3663-4ed5-8fd2-36f98440edb8 Bulgaria | |
| f0cd56dd-f4b6-41b5-aeb8-fde1a16fa770 Portugal | |
| b157c177-58c4-424e-8d99-f5b520a30a49 Belgium | |
| 6e67ce78-4dd0-44e7-80ca-35fc40b96dcf Germany | |
| 96c9eeb7-a9f6-4e4d-a7ce-ab515599afb9 Belgium | |
| e2ac55a2-b54a-4f88-87f0-ce28ae6d48a4 Hungary | |
| 968eaf8a-c313-4d00-aa50-2dca51310cc7 Spain | |
| 070d7433-cff7-4294-8da6-825adb15c70b Germany | |
| e511955c-66c8-4bf7-a653-4e9bab87760b Denmark | |
| 048739cb-545f-4dc8-8afb-67613401c504 Poland | |
| 38a433fd-3a5c-448a-b669-2606295e4db8 Germany | |
| 0d36d403-18b7-4b35-aaf2-00a55973b68d Norway | |
| 4d8f0f82-d827-4c6e-929b-4915c422e1ce Sweden | |
| 81c156c8-3a90-4a83-9372-914110b72531 France | |
| f09ae23d-0211-42aa-86cd-9d51010d44ea Germany | |
| 28ebc3b4-00fd-4ba6-b927-39a798244a41 France | |
| 5bb33109-3149-442e-84c4-6f80fffa2dba Germany | |
| c5f4de60-4cb4-4d85-bf9f-0b51d20d9beb Greece | |
| ab94bf49-05b6-4126-90ec-5fb7e0d7dadd Croatia | |
| 2751b8be-858f-4a3c-8951-747757cc5e5d Czech Republic | |
| 849d619e-2ed0-463f-b4b5-cfd47e2b2855 Poland | |
| 46348c38-1cac-4e0f-80e3-9677e94ee36d Finland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT6NE3800KFF000XXX |
| E-Number (Norway) | 4380517 |
| EAN | 8056221008013 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 9.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 12 kg |
| Package Level 1 EAN | 8056221008013 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Motor Protection |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1190 |
| 1SDH002065A1245 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 53.4 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 30 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 10 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 30 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 2 Poles in Series 20 kA | |
| (750 V DC) 3 Poles in Series 18 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip M Dip I |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT6 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2825 |
| Mechanical Drawings | 1SDH002012A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002012A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 800 A |
| Rated voltage (EF003977) | 690 V |
| Adjustment range short-term delayed short-circuit release (EF007129) | 480.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 800 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |