ABB 1SDA100572R1 1SDA100572R1 ABB XT5X 630 INTERRUPTIVE PART 4p F F View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SDA100572R1 ABB XT5X 630 INTERRUPTIVE PART 4p F F

1SDA100572R1

100572

ABB

1 Pcs.

XT5X 630 INTERRUPTIVE PART 4p F F XT5X 630 BREAKING PART 4p F F

Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An ABB interruptive part circuit breaker (1SDA100572R1) provides robust modular circuit protection for industrial power distribution systems. These components are designed to house and operate trip units that safeguard electrical installations against overloads and short circuits.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • ABB EcoSolutions: Yes
  • ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
  • End Of Life Disassembling Instructions: 9AKK108468A2353
  • Environmental Product Declaration - EPD: 9AKK108468A9746
  • Extended Product Lifetime: Product Modularity
  • Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 59.6 %
  • REACH Declaration: 9AKK108466A1425
  • RoHS Declaration: 9AKK108466A1424
  • RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
  • Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
  • Toxic Substances Control Act - TSCA: 9AKK108467A8326
  • Environmental Information: 9AKK108467A6707
  • E-Number (Finland): 3641470
  • E-Number (Norway): 4380458
  • EAN: 8056221006484
  • Minimum Order Quantity: 1 piece

More info

▲
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2353
Environmental Product Declaration - EPD9AKK108468A9746
9AKK108468A1893
Extended Product LifetimeProduct Modularity
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 59.6 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
Environmental
Environmental Information9AKK108467A6707
Ordering
E-Number (Finland)3641470
E-Number (Norway)4380458
EAN8056221006484
Minimum Order Quantity1 piece
Customs Tariff Number85389099
Dimensions
Product Net Width186 mm
Product Net Height205 mm
Product Net Depth / Length103.5 mm
Product Net Weight4.55 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width305 mm
Package Level 1 Height285 mm
Package Level 1 Depth / Length370 mm
Package Level 1 Gross Weight12.5 kg
Package Level 1 EAN8056221006484
Additional Information
Product Main TypeSACE Tmax XT
Product NameMoulded Case Circuit Breaker
Product TypeBreaking Part
VersionF
Technical
Electrical Durability5000 cycle
60 cycles per hour
Mechanical Durability20000 cycle
120 cycles per hour
Number of Poles4P
Order Multiple1 piece
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)1000 V
Rated Operational Voltage690 V AC
750 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 200 kA
(230 V AC) 200 kA
(240 V AC) 200 kA
(380 V AC) 200 kA
(415 V AC) 200 kA
(440 V AC) 180 kA
(500 V AC) 150 kA
(525 V AC) 120 kA
(690 V AC) 100 kA
(250 V DC) 2 Poles in Series 100 kA
(500 V DC) 2 Poles in Series 100 kA
(750 V DC) 3 Poles in Series 100 kA
Rated Short-time Withstand Current Low Voltage (Icw)6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(220 V AC) 200 kA
(230 V AC) 200 kA
(240 V AC) 200 kA
(380 V AC) 200 kA
(415 V AC) 200 kA
(440 V AC) 180 kA
(500 V AC) 150 kA
(525 V AC) 120 kA
(690 V AC) 100 kA
(250 V DC) 2 Poles in Series 100 kA
(500 V DC) 2 Poles in Series 100 kA
(750 V DC) 3 Poles in Series 100 kA
Rated Uninterrupted Current (Iu)630 A
Short-Circuit Performance LevelX
StandardsIEC60947-2
Sub-typeXT5
Terminal Connection TypeFront
Certificates and Declarations
Data Sheet, Technical Information1SDC210100D0206
1SDC210099D0206
Declaration of Conformity - CE9AKK107680A2824
Instructions and Manuals1SDH002011A1001
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification CodeQ
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.