View larger
1SDA100553R1
100553
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2353 |
| Environmental Product Declaration - EPD | 9AKK108468A9746 |
| 9AKK108468A1893 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 83044b39-d9ae-4dc9-8e9f-3f7842bd3196 Italy |
| Simplified SCIP | 4569e9ab-b943-4457-9b5f-2ce373828ca4 Germany |
| 472d54b9-6f6b-47d8-ab52-569dff28da87 France | |
| 637d5125-4bb4-47fa-ad02-259f7c12a51c Netherlands | |
| 857a5547-d4bf-44a5-9ff3-82bb70454c87 Spain | |
| 8b2d1ef0-0900-4668-9c11-e99e25a0b55e Netherlands | |
| 55aa781a-0955-4503-88a4-fe8e55d25e03 Poland | |
| 0a364551-ce7f-4179-b720-32f1e94ff1ce Norway | |
| e11badc7-9513-49e9-91b6-81db5bdd9b3e Finland | |
| 5c7837e3-6430-4746-87a0-6ad733ab884d Netherlands | |
| 1b2771d3-db28-4d02-bef8-cf409998370b Germany | |
| 5c10047b-0abb-4fb1-9e02-635f88f5bb31 Denmark | |
| 454eccf3-8888-48cd-8b48-9314b6ffbabe Germany | |
| 06c2d02e-8cee-43a7-acab-10e631d329d4 Croatia | |
| d14c76dd-691a-45eb-8a0f-05a91b71f217 Czech Republic | |
| 9d96f0c7-26db-4468-b803-c0fc24d13dff Poland | |
| beb1e3e8-39ac-40f1-917d-bcb51a3b7450 Netherlands | |
| a0f0a9d0-7b3f-4789-8b05-6dff6f61f2a3 Netherlands | |
| ba8e6ac3-54c2-48d1-b59b-2ea2d269cdc4 Estonia | |
| df31fd9e-9f9f-4a1a-85da-1ba3ca68e812 Portugal | |
| 7ebc288d-bd09-47de-8ff1-f2e97131985a Bulgaria | |
| dae9cf33-0515-4b9f-a9bc-c56c62464164 Sweden | |
| 533138b6-c17b-478b-972c-c5abba0dacaa Poland | |
| d2a509bb-3e49-4ebb-95c8-00d3531d6c3e France | |
| ff9da9e5-3b09-4167-be6d-4503b406dae7 Sweden | |
| 1b771778-a2f2-4345-848a-2f4d221e7754 Greece | |
| 3ad44d0c-17d7-4d5b-a99f-f52c81cc238b Germany | |
| 1ded4572-8821-4cba-aa13-581ebfc9330e Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| E-Number (Finland) | 3641399 |
| E-Number (Norway) | 4380449 |
| EAN | 8056221006293 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85389099 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 4.15 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 248 mm |
| Package Level 1 Height | 240 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 4.5 kg |
| Package Level 1 EAN | 8056221006293 |
| Additional Information | |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Breaking Part |
| Version | F |
| Technical | |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 750 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 2 Poles in Series 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 2 Poles in Series 25 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |