View larger
1SDA100551R1
100551
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2353 |
| Environmental Product Declaration - EPD | 9AKK108468A9746 |
| 9AKK108468A1893 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 6ed89b80-406d-4fdd-821b-b305746782d7 Italy |
| Simplified SCIP | 1685e0f4-29e7-4e28-b7e9-d866b7e356d9 Germany |
| 28fc462f-0318-4a04-8768-7aadf00941cf Netherlands | |
| 33b888c1-f359-4d7e-ac0d-bec8ed2d5181 Spain | |
| 896785e8-9a96-41ff-9551-c35bf9d80daa Netherlands | |
| 75147bab-0cd4-4076-810c-0e60e34861a4 Poland | |
| 3f1bcb65-a96a-4c56-9e20-37aea4ff8af2 Norway | |
| f257a8e5-5fc8-47cf-96b4-13324e19ad7d Finland | |
| 3d7fe2f2-13b9-4768-a2ec-0dccbc5da0b9 Netherlands | |
| cb3b3255-fc76-42ec-8ac4-9aa235cebf05 Germany | |
| 4ecb141e-522f-4e46-99a3-0b7d06fb027a Denmark | |
| 06275461-d62d-431b-ac05-6c7bf5694ff1 Germany | |
| 9ae0af0d-d404-4c25-a23c-d07f95e59fa8 Croatia | |
| a12dc1e4-45b2-40ef-8ac9-9e51f6592254 Czech Republic | |
| c2a09c7b-df61-4923-8769-6f61e68a534d Poland | |
| 7a53a9da-d9c2-4ace-88bb-ca24b23e214a Netherlands | |
| 04870cd6-1382-4f91-b296-a03c24c35270 Netherlands | |
| c9a8f67d-dd11-49d4-964a-17e3d384eee1 Estonia | |
| a0353b7d-8cc3-493b-9d5e-75dc8d77555a Portugal | |
| 13ccca24-d1bb-43d0-8126-1a7c07844227 Bulgaria | |
| 5888fa81-8d49-4c3a-90a1-ce176e330e19 Sweden | |
| 28fc8b75-e399-4bbb-84bd-d63658197b0f Poland | |
| 4b8bc105-67c4-4aaa-8abb-53cb9dc6ed59 France | |
| 5b29fef9-6158-4d51-a1ce-c3cd29512831 Sweden | |
| 901067a5-6a0a-41a4-8ba2-892bf2ca2551 Greece | |
| e5a98e56-3c8d-4206-a985-0f8494277aa6 Germany | |
| 457b8b69-e222-4236-bc39-ce2b43580c0d Germany | |
| d1998aaa-b188-4f92-8690-33c1a37d5cfa France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| E-Number (Finland) | 3641398 |
| E-Number (Norway) | 4380324 |
| EAN | 8056221006279 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85389099 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 3.425 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 248 mm |
| Package Level 1 Height | 240 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 3.8 kg |
| Package Level 1 EAN | 8056221006279 |
| Additional Information | |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Breaking Part |
| Version | F |
| Technical | |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 750 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 2 Poles in Series 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 2 Poles in Series 25 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |