View larger
1SDA100531R1
100531
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 11636c0d-8eda-4bc6-93e9-8b37749b6a65 China |
| Simplified SCIP | 3bdc4296-ee7d-455e-a207-626c6862d5c6 Czech Republic |
| 1261695d-3866-4716-b37d-e0511226e87d Poland | |
| f55db9d3-3404-4c32-a6fa-dd6e3dca4831 Germany | |
| b482033c-f727-4812-a5d4-509b353b7d2a France | |
| deaeb6ab-1667-4fc1-9ade-dc75e84a5a76 Sweden | |
| 6e388761-178a-46d6-a910-4be2499c0b39 Bulgaria | |
| 46809e63-721b-4155-a8cb-7bc78b9a621f Poland | |
| 9f77a9bd-bff6-40c3-8c74-00ef35f69abb Hungary | |
| 8c6b3552-88ac-4f5a-94ff-70c5fe8cd7df Spain | |
| e29dbd65-54ab-4bd1-bd16-0b99dd889885 Germany | |
| 464e0692-1766-42fc-ba90-30258b966efc Denmark | |
| 65e4d1f8-06a5-4f75-9819-494d5074c24f Portugal | |
| be40fda4-a57c-4f0e-8e7b-2560d302e2ef Germany | |
| 1ab95617-10ab-46e5-9589-ee3d90e0de8d Germany | |
| 0c3fa4a8-3391-4270-8ea1-66064e2f3e73 Belgium | |
| bb34c5ae-cb41-4507-930a-42e1139d1f0e Norway | |
| 43302cbe-d667-41e4-9176-71c1fd4da2da Belgium | |
| b5355fa5-3c26-44ef-930b-37cb69e67655 Estonia | |
| e39e4df1-a0d8-4fe0-b378-9584a9dae6fc Greece | |
| 6f4b6b4a-63af-4c2e-aa71-aba8cb5f9364 Netherlands | |
| b15f9225-f394-4547-b3f8-9a7bc1760006 Hungary | |
| a40aadd1-0b2a-4127-976d-60b52ebe6b32 France | |
| 5b021139-3aff-4122-8fc5-3b0533129f0d Poland | |
| b7f42bbf-79d9-4b8a-970f-e2ecc344dc82 Finland | |
| ffdce452-ca17-41b9-8846-94e6661f6aee Sweden | |
| f89fdf8b-626f-42aa-92ed-ae1fdb8c0a1e Germany | |
| c5793961-7911-42ca-bd48-e0d931375a2d Croatia | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5HE432AFFF000XXX |
| E-Number (Norway) | 4380439 |
| EAN | 8056221006071 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 6.4 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 6.888 kg |
| Package Level 1 EAN | 8056221006071 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1183 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | 11.6 W |
| Rated Current (In) | 320 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 40 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 40 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |