View larger
1SDA100495R1 ABB XT5H 630 Ekip Dip LSI In 630 3p F F
1SDA100495R1
100495
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb 1SDA100495R1 ABB XT5H 630 Ekip Dip LSI In 630 3p F F operates as a molded case circuit breaker built for reliable electrical protection in industrial automation and power distribution applications. Technicians rely on such breakers to disconnect faulty circuits automatically during overloads and short-circuit events, safeguarding critical machinery and electrical infrastructure.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2354
- Environmental Product Declaration - EPD: 9AKK108468A1899
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 59.6 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: f1b36f81-ce01-44bb-b168-083fe1e98b67 China
- Simplified SCIP: 445eb84c-ac5c-4822-894f-f56c580b0c56 Hungary
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT5HE363BFFF000XXX
- E-Number (Norway): 4380306
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | f1b36f81-ce01-44bb-b168-083fe1e98b67 China |
| Simplified SCIP | 445eb84c-ac5c-4822-894f-f56c580b0c56 Hungary |
| e08eb515-eacb-46e5-a026-6aa2b3e024e0 Spain | |
| 90f94042-c8bc-4c33-9d4c-454f579b86b6 Germany | |
| 01f12f9d-7600-4270-b745-ca5113190a90 Denmark | |
| 3bc856f8-f7d5-4a8a-be43-9eb2c8e3045b France | |
| eb16fa60-87eb-4c80-a3d2-b0ba0671c421 Poland | |
| db253149-b7d9-476a-a2c3-c668632f1127 Bulgaria | |
| a775f124-70d6-4da6-a587-db80c804a96b Germany | |
| 2add7d66-7c76-4457-8bb2-b623a100a149 Estonia | |
| c3644518-019d-46ca-85e6-c02259c7776c Belgium | |
| 11b43af9-d553-49c9-888b-0f246738f6b2 Portugal | |
| 3704242c-4778-4fef-964f-ef61bdecc72a Germany | |
| 6b98581a-9fe5-4a68-b7ca-c54031e5f558 Sweden | |
| 9e0818b8-1989-428a-987c-393743e565e7 Croatia | |
| dc092555-b655-49ad-8854-7326d2299c61 Czech Republic | |
| 06c30d99-7aeb-4187-ad46-9ed0c73a7483 Norway | |
| 88eb8bdd-48f1-457c-962f-0b7189831007 Germany | |
| c1e545ef-a651-4ce5-89a2-42975a15b7df Sweden | |
| 70290079-dbd2-494f-9541-b8756b2d6d4a Poland | |
| 30f5d423-00e1-49e6-9566-d6bc726863b9 Finland | |
| 06ad1735-7c3d-4715-963e-feedb2f2bf39 Poland | |
| aebc539f-f24c-454e-9cb5-1b172a46c486 Netherlands | |
| 56016b7b-2c75-482c-901f-83faf03df0be Hungary | |
| fc64dcbb-8f16-4112-9707-e9545dfeee89 France | |
| c2845d90-e9b1-4318-b1f5-39c0788f4468 Greece | |
| f608c74d-e5b5-486a-b846-faa00d1ccf30 Belgium | |
| 0f2052b1-d85c-4fc1-b17f-ec0df6d0e7c7 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5HE363BFFF000XXX |
| E-Number (Norway) | 4380306 |
| EAN | 8056221005722 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 4.82 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 5.308 kg |
| Package Level 1 EAN | 8056221005722 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1115 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 45 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 30 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 40 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |