View larger
1SDA100491R1
100491
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 64c8187e-2a1f-4159-9f58-a5c83cd24576 Italy |
| Simplified SCIP | 8a505a4b-0b79-4909-bebc-1fdf4d7265aa Poland |
| 7030c655-4ad3-4c47-9860-b3a13ade55cf Netherlands | |
| 0ac7fefb-e020-4898-838e-a890a390c582 Czech Republic | |
| 4c0398b1-5cd1-48d0-bb03-a5aa22c32ffa Belgium | |
| 65ab7ebc-db66-4da1-bb8f-0fa1fe6e9162 Germany | |
| 241dbe8b-c9ca-4671-abf6-9b97c424e7e8 Germany | |
| 04bcfadb-dea1-47bd-b61e-f3aded9a7993 Croatia | |
| 516083f0-d338-44a0-9821-a29ae5f51ca6 Denmark | |
| 949939d5-0392-470c-a105-9cfaca1e5f23 Poland | |
| 4c09c8a1-2ab7-467f-9256-5d66a9e56362 Germany | |
| 283bfbcf-57e7-40a2-8623-2580246aec8d Spain | |
| 2f790f8d-4d5c-40b2-99cc-93b3aaaf65ec Belgium | |
| 72c3b018-dc61-4a79-ba02-624017765819 Hungary | |
| a3cc564f-2082-4ade-a31d-12486b318ee7 Germany | |
| 05563c05-e14f-4747-b744-350d252b93ce France | |
| 3d78e909-8246-4599-963e-8307c5ea6acd Hungary | |
| 365a7cc5-9887-4bdd-9701-c5acb85796c8 Poland | |
| e101aaeb-0702-42ca-9532-50159dc5f217 France | |
| 56fb15be-52a4-463b-9913-cd72f94806f3 Sweden | |
| 84317218-14ed-4f7c-a248-78e9900cf4e9 Germany | |
| cca9120c-2047-4d5d-827f-d7cc3be18739 Bulgaria | |
| 88f617dd-b74b-4bda-8f62-8a40e99cac79 Estonia | |
| 7bd07588-68fd-49ec-bdd0-ebf7b0a7db2a Greece | |
| 0983d5e0-53b1-4815-ba84-ccc2008e3f34 Portugal | |
| a4ed1582-77d3-4557-8b11-7e6b2ead7cac Sweden | |
| 240d7d4f-6e2a-4a93-b149-3de7195be719 Finland | |
| b35ef40f-2808-45b1-b150-f08f08d84f63 Norway | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5HE363BEFF000XXX |
| E-Number (Norway) | 4380302 |
| EAN | 8056221005685 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 4.82 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 5.308 kg |
| Package Level 1 EAN | 8056221005685 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1115 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 45 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 30 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 40 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | Ekip Dip LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 630 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 252.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 630 A |
| Adjustment range undelayed short-circuit release (EF007131) | 630 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |