1SDA100474R1 ABB XT5S 400 Ekip Dip LSIG In 400 4p F F
1SDA100474R1
100474
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This 1SDA100474R1 ABB XT5S 400 Ekip Dip LSIG In 400 4p F F functions as a molded case circuit breaker designed to protect electrical systems from overloads and short circuits in commercial and industrial power distribution networks. Units of this type provide reliable switching and fault interruption for downstream equipment.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2354
- Environmental Product Declaration - EPD: 9AKK108468A1899
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 59.6 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 91f0ab91-05a9-42ae-80a3-d974dc1396fc Italy
- Simplified SCIP: bc6bacb4-b68a-4d35-88a3-ee881b45c01f Belgium
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT5SE440AGFF000XXX
- EAN: 8056221005517
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 91f0ab91-05a9-42ae-80a3-d974dc1396fc Italy |
| Simplified SCIP | bc6bacb4-b68a-4d35-88a3-ee881b45c01f Belgium |
| 314fa460-71b5-4844-b1d9-70a033403aec Finland | |
| 186257b2-d3b0-4e1f-9978-939b080c5e4a Poland | |
| fd9c4c65-73c9-4a59-a2c8-e27c3c3482fb Germany | |
| 60539d9f-101f-432d-9a63-879ade7aeeb5 Croatia | |
| 7b7dbc97-2261-46df-934c-1e3756d1d607 Denmark | |
| e76ecc05-2e1f-4eef-b251-068d1d039503 Germany | |
| 51158d39-1abc-4659-afcd-b6f31879b6cb Poland | |
| 5056473e-33dd-4163-8fc0-a617eb138336 Czech Republic | |
| 75a60f34-27ec-4f48-ae54-c50c2e6d52e9 Netherlands | |
| d942f185-f1ae-46c9-8be8-ef11bc0628be Germany | |
| 79b0f738-26c6-4bde-a5b6-cc23ec4d458f Greece | |
| 3d857191-c247-46ed-bb9f-f560c6acb97a Estonia | |
| d3a0a935-d748-4b7e-9203-298ccea1917b Bulgaria | |
| baa61dbd-2e75-4dbf-9ccc-88f8d9b587e4 Portugal | |
| db60e273-cbd6-43eb-870c-ad7661e5d496 Poland | |
| 6da08a8e-754d-44a5-ae6e-4a14ae04754c Sweden | |
| 5997ce7a-3e25-4b92-80a5-ddb563b0b09c Sweden | |
| 0c9f02dd-1219-4457-b662-a3720238659e France | |
| 97589d36-de64-45e0-88eb-ddbd30812b9a Germany | |
| b7b51802-f8f2-4224-a777-592e3635872f Norway | |
| 01fa1e0d-a7c1-4e86-a1b1-e7a7759e2515 Spain | |
| 70e971e5-1caf-446b-9d57-dabf49eba5f8 Belgium | |
| 03a07112-23f6-42b3-b067-4b0ad3e5fbfd France | |
| 6e8c4368-f2e4-4234-abe4-466925923a8a Germany | |
| c76dcf1d-a4ba-4c8f-9ad8-fc82350d4b9b Hungary | |
| 1268fe12-a37a-47ec-9c3d-edfa2d1043c2 Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5SE440AGFF000XXX |
| EAN | 8056221005517 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 6.4 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 6.888 kg |
| Package Level 1 EAN | 8056221005517 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1183 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | 19 W |
| Rated Current (In) | 400 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |