View larger
1SDA100474R1
100474
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 91f0ab91-05a9-42ae-80a3-d974dc1396fc Italy |
| Simplified SCIP | bc6bacb4-b68a-4d35-88a3-ee881b45c01f Belgium |
| 314fa460-71b5-4844-b1d9-70a033403aec Finland | |
| 186257b2-d3b0-4e1f-9978-939b080c5e4a Poland | |
| fd9c4c65-73c9-4a59-a2c8-e27c3c3482fb Germany | |
| 60539d9f-101f-432d-9a63-879ade7aeeb5 Croatia | |
| 7b7dbc97-2261-46df-934c-1e3756d1d607 Denmark | |
| e76ecc05-2e1f-4eef-b251-068d1d039503 Germany | |
| 51158d39-1abc-4659-afcd-b6f31879b6cb Poland | |
| 5056473e-33dd-4163-8fc0-a617eb138336 Czech Republic | |
| 75a60f34-27ec-4f48-ae54-c50c2e6d52e9 Netherlands | |
| d942f185-f1ae-46c9-8be8-ef11bc0628be Germany | |
| 79b0f738-26c6-4bde-a5b6-cc23ec4d458f Greece | |
| 3d857191-c247-46ed-bb9f-f560c6acb97a Estonia | |
| d3a0a935-d748-4b7e-9203-298ccea1917b Bulgaria | |
| baa61dbd-2e75-4dbf-9ccc-88f8d9b587e4 Portugal | |
| db60e273-cbd6-43eb-870c-ad7661e5d496 Poland | |
| 6da08a8e-754d-44a5-ae6e-4a14ae04754c Sweden | |
| 5997ce7a-3e25-4b92-80a5-ddb563b0b09c Sweden | |
| 0c9f02dd-1219-4457-b662-a3720238659e France | |
| 97589d36-de64-45e0-88eb-ddbd30812b9a Germany | |
| b7b51802-f8f2-4224-a777-592e3635872f Norway | |
| 01fa1e0d-a7c1-4e86-a1b1-e7a7759e2515 Spain | |
| 70e971e5-1caf-446b-9d57-dabf49eba5f8 Belgium | |
| 03a07112-23f6-42b3-b067-4b0ad3e5fbfd France | |
| 6e8c4368-f2e4-4234-abe4-466925923a8a Germany | |
| c76dcf1d-a4ba-4c8f-9ad8-fc82350d4b9b Hungary | |
| 1268fe12-a37a-47ec-9c3d-edfa2d1043c2 Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5SE440AGFF000XXX |
| EAN | 8056221005517 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 6.4 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 6.888 kg |
| Package Level 1 EAN | 8056221005517 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1183 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | 19 W |
| Rated Current (In) | 400 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 400 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 160.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 400 A |
| Adjustment range undelayed short-circuit release (EF007131) | 400 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |