View larger
Images are for illustrative purposes only. Please refer to data sheet for details
1SDA100467R1 ABB XT5S 630 Ekip Dip LS/I In 630 4p F F
1SDA100467R1
100467
ABB
1 Pcs.
XT5S 630 Ekip Dip LS/I In=630 4p F F
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb circuit breaker delivers precise fault interruption and current regulation for complex electrical distribution architectures. Its intelligent tripping mechanisms help prevent unplanned downtime in industrial environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2354
- Environmental Product Declaration - EPD: 9AKK108468A1899
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 59.6 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 836529eb-74c9-4dd0-b3f3-9944f75b70ff Italy
- Simplified SCIP: 9941355a-c94a-4804-8a0a-b270027b0cf6 Belgium
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT5SE463BEFF000XXX
- E-Number (Finland): 3641347
- E-Number (Norway): 4380421
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 836529eb-74c9-4dd0-b3f3-9944f75b70ff Italy |
| Simplified SCIP | 9941355a-c94a-4804-8a0a-b270027b0cf6 Belgium |
| 137044b9-d3ba-4c3b-9878-661ba0df02d8 Finland | |
| 12bd3db4-5714-4300-af38-c6df4e2ee9c8 Germany | |
| be9425a7-4327-4a5a-aa97-c50c818da1c0 Germany | |
| 54fc74ab-af64-498d-a7a8-a0468b53b9d5 Poland | |
| fa8b5c78-842d-4a27-bd7c-82708447be33 Denmark | |
| 6bc01d12-05aa-4906-80b5-8028ee744a4f Germany | |
| 37934511-d407-4ef8-8dd0-9c22bcb10683 Czech Republic | |
| ac4a63ad-119d-43c2-8467-e730b1b91ac7 Poland | |
| 55f030cb-486b-40f9-8f36-43f9b2cedc2a Croatia | |
| 2c8398e9-b72c-4c08-acda-7d56445df17a Netherlands | |
| 67ed9b1f-1c0d-4b6b-88c5-6845ffb5f12e Germany | |
| c75a5d15-b546-42d5-8419-6239b374f856 France | |
| 3cbb813e-2aaf-4506-be49-ee464665e949 Sweden | |
| f255b1fa-f095-457a-bdf8-c7326fab7314 Sweden | |
| 94ee46b7-43b8-4221-87fc-7d832c926182 Poland | |
| 43e4fd24-2cfe-4dd9-a6e5-2294068f150f Belgium | |
| 68729711-0ff3-4cbb-b4b7-cc650e77c5c7 Spain | |
| 20dc6c11-373d-4e4e-b3d9-db59cfc70cd2 France | |
| 0052f38b-2d4b-40c8-bc9f-7330c439f7a4 Hungary | |
| b4a16ebc-fff4-401d-9ed9-7841bb2633b6 Germany | |
| 6d121e2d-6110-48e8-894c-8f813919086d Hungary | |
| 3160011b-3986-4ca8-8c63-b4f8c5e200a4 Norway | |
| 9625d679-f1a4-48f9-8b43-9a1799bf3ed6 Bulgaria | |
| 0d4fa30d-f0ea-4738-8a1d-1353b9e95f83 Portugal | |
| 49388295-8d2b-4e2b-bcd1-7e671d93f711 Estonia | |
| c98a053f-6c9a-4d7c-8535-77ab884a2e0b Greece | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5SE463BEFF000XXX |
| E-Number (Finland) | 3641347 |
| E-Number (Norway) | 4380421 |
| EAN | 8056221005449 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 6.4 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 6.888 kg |
| Package Level 1 EAN | 8056221005449 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1183 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | 45 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | Ekip Dip LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |