View larger
1SDA100451R1
100451
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 43fc01ec-48a1-4bcf-9ca0-ef661f57950c China |
| Simplified SCIP | 01ff6b00-1a56-45e0-8f64-6c9e9921e9e1 Germany |
| 85f0fe12-f69e-4fe4-b7ff-55cff12dae88 Germany | |
| 6e06c06f-e499-43f4-8d4f-80794054a058 France | |
| 222d501e-f846-4c27-98a2-b574d614380e Sweden | |
| 055f042f-dbb4-43d9-a664-4d1bd68ae3a2 Portugal | |
| c8c6f764-bf9c-4da5-b729-f52a77570c8b Poland | |
| 7b1cb281-7f13-4cc3-b2f0-c67710262dad Bulgaria | |
| 665e9554-25d0-4df4-a619-88f6087f8f6a Finland | |
| 5ae88ce1-6fd9-4981-ad6d-44c7b1602af2 Germany | |
| bd3f2fb2-84cb-4c1b-b1eb-385b1c66d027 Norway | |
| ee5ddec3-00a0-4c22-ad4d-27be78d21c4a Poland | |
| 19d0d2ff-194f-4a88-97e0-8f83ca660cfd Sweden | |
| f1b1efdc-fb94-4caf-b017-c81c4ebd4466 Hungary | |
| 76284ad3-2d7b-471a-99f3-9d27503b4525 Netherlands | |
| 2613fe8c-ada6-45dc-9bc1-7a913544632e Germany | |
| e3cfdee8-fbdc-4a16-a22f-d761d046b3b3 France | |
| 27b8346a-57fa-4250-a458-f4c657441985 Czech Republic | |
| e6935b28-7686-45f0-8b87-265aa394e061 Croatia | |
| b70bc06f-5759-4080-b9c9-69ea6e2620b7 Poland | |
| 6218aad6-2b73-4d25-86fb-0288f6312b48 Denmark | |
| 3cf8c040-a214-4cc0-8858-be9fc1511042 Belgium | |
| 2554311e-5e43-45bf-9c75-1054fe6d709e Spain | |
| 20ca4b49-0938-4255-85b9-8b9c1790edaa Hungary | |
| bee06edc-c105-4313-85d2-9abc16677f20 Greece | |
| 444f0f8b-366b-4060-8f5f-a0b0d5c2d669 Belgium | |
| f94d2809-e705-46ca-b76e-d72777f04165 Estonia | |
| 229035fa-21ac-4690-b21c-909555b5736b Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5SE363BCFF000XXX |
| EAN | 8056221005289 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 4.82 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 5.308 kg |
| Package Level 1 EAN | 8056221005289 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1115 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 45 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | Ekip Dip LIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 630 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 252.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 630 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |