View larger
1SDA100433R1 ABB XT5S 630 Ekip Dip LSIG In 630 3p F F
1SDA100433R1
100433
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Abb 1SDA100433R1 (XT5S 630 Ekip Dip LSIG In 630 3p F F) is a molded case circuit breaker engineered to protect electrical distribution circuits from overloads and short circuits. Industrial installations rely on robust circuit breakers like this to isolate faulty equipment and ensure personnel safety during maintenance or fault events. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2354
- Environmental Product Declaration - EPD: 9AKK108468A1899
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 59.6 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: dd5de06a-4a47-47e3-9137-d54b1d8fa4e1 Italy
- Simplified SCIP: e19177cb-1f74-4d01-94fe-af6c0bf576f9 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT5SE363BGFF000XXX
- EAN: 8056221005104
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | dd5de06a-4a47-47e3-9137-d54b1d8fa4e1 Italy |
| Simplified SCIP | e19177cb-1f74-4d01-94fe-af6c0bf576f9 Germany |
| 19ef172c-e6ff-4582-accc-7283ce00cddb Netherlands | |
| c566848d-df6b-4a23-b31f-26bc15a03a5e Germany | |
| a57e9ecf-cc5d-47ef-93e5-90dd8d01936c Denmark | |
| 4513736d-94bc-48e3-9ac4-a890792997a7 Germany | |
| 7b78baaf-4762-422b-846c-c2f20104e158 Finland | |
| 4c8f7282-4e46-47e3-a360-ec3931c18634 Germany | |
| 58d7f76e-9b9a-4a07-ac8c-8633fcdd7585 Croatia | |
| d7e72216-1e47-4f7c-95ea-9d4888c8b798 Czech Republic | |
| 59c9a687-7eaa-428e-8ad9-2184ce534760 Poland | |
| 80ed9b8b-31e9-4fcd-b4bb-0e4501b0d8b7 Netherlands | |
| 3c1fb144-5e7d-4cd8-bce9-d538af49d72d Netherlands | |
| a23757d1-3ccf-4b80-92e0-dc92c35fdff7 Estonia | |
| 267936ab-8992-43aa-acdc-e166deff3359 Sweden | |
| 88000b29-0e08-46db-ab55-9f91a9693a2c Germany | |
| b442e425-e691-497b-a4f1-97b3e7566d3f Netherlands | |
| 0243115f-5c3e-4b23-9d94-faa45663e325 Spain | |
| e5e69ff5-c99d-47eb-a8a3-0bd73f0a0adb Netherlands | |
| 2a131f75-af15-4bd0-865e-93b5ddc93486 France | |
| ca18db80-0b61-4fa5-99b6-e2604c860828 Greece | |
| 4ecfda2a-8164-4ceb-a777-aaf9d2b79ae8 Portugal | |
| 9fbf8079-60ef-46ef-82f9-0dbb407714ff Bulgaria | |
| c8dbe7e7-40f0-4b0d-8493-c5bcc2c70826 Sweden | |
| 92e6bf63-178e-4621-aaf4-b1307143d122 Poland | |
| 33ff7f0b-77d3-4007-a9f1-855a6c4931c1 France | |
| e97372ca-305f-4f2d-8001-cda9037d5391 Poland | |
| 59581575-c038-4e3e-a662-eaf6f40293cb Norway | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5SE363BGFF000XXX |
| EAN | 8056221005104 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 4.82 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 5.308 kg |
| Package Level 1 EAN | 8056221005104 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1115 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 45 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |