View larger
1SDA100385R1 ABB XT5N 400 TMA 400-4000 4p F F InN 100%In
1SDA100385R1
100385
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A molded case circuit breaker like the 1SDA100385R1 ABB XT5N 400 TMA 400-4000 4p F F InN 100%In is deployed in electrical switchgear to protect distribution circuits from dangerous overcurrents and short circuits. These vital components interrupt abnormal current levels swiftly, safeguarding downstream equipment and facility personnel.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2353
- Environmental Product Declaration - EPD: 9AKK108468A9746
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 59.6 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: eea60081-741a-49ae-b7b1-2ddaec1bf8a5 Italy
- Simplified SCIP: 7e35ce4b-2b81-467f-94af-fa803469fe73 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT5NE440ABFF000XXX
- E-Number (Norway): 4380399
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2353 |
| Environmental Product Declaration - EPD | 9AKK108468A9746 |
| 9AKK108468A1893 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | eea60081-741a-49ae-b7b1-2ddaec1bf8a5 Italy |
| Simplified SCIP | 7e35ce4b-2b81-467f-94af-fa803469fe73 Germany |
| 0903d12e-6f5e-428c-ad9b-f0c46cd6951e Netherlands | |
| 4e4a3233-9de4-48d3-8c48-91bb2a83690d Poland | |
| 49ceef5b-aa3f-48a4-b7a0-c1c70a915fde Sweden | |
| 65fc2e41-4e6d-41b7-bc7c-3adc0b782157 Norway | |
| e9bbae4d-29f3-4ccf-889d-053f8ed9b25e Finland | |
| 3c05b67d-e43f-45c7-8716-2592e719c3f7 Netherlands | |
| b5eb4cd8-90ad-454b-97fc-65fbb20f234d Germany | |
| b94d6ae9-8433-40e5-9fda-0c7c8a3011f5 Denmark | |
| ec0af2ae-0b43-40cf-a928-da9dcb6968ee Germany | |
| c69df494-adc8-4c4d-85b4-4a36e270a27b Croatia | |
| 83228fc3-3495-43ff-bd2d-b4f2f63b0e3f Czech Republic | |
| 18aea661-5326-45e1-8853-0c911155498d Poland | |
| 40bd1dbf-1cff-4d60-be49-a85bb95fecd0 Netherlands | |
| bd1f85b9-d257-4a13-9291-808836ae3c5d Netherlands | |
| ed3d54c8-d312-486c-9d1f-7cc9cda513bd Estonia | |
| 42d0a369-8f59-4b20-ad3f-e23943b31e06 Greece | |
| 33987e54-5176-4f49-bdf2-1cb0b6bc205c Portugal | |
| 6e2b437b-d283-476c-a924-19bcc3bfc8ce Bulgaria | |
| 5ad2140e-b4a9-4a1b-ac2a-58672db38636 Sweden | |
| 7daf2e63-692e-4730-9592-b67188fd0eb0 Poland | |
| 66fc87c2-5e22-4313-a434-083cbb4beed9 France | |
| 7ce1528a-28f9-4d44-bf45-ae4f51b5586c Germany | |
| 2cd1fb2c-692c-4caf-ae7e-2ce1d5802d79 Germany | |
| 1e53aea6-1b2a-4b4d-8a71-5397613aca53 France | |
| 5fde2033-e8dd-470f-8114-0bda083a9a8e Netherlands | |
| 9f7a73c9-6e24-4cf9-b719-d1969037fe4b Spain | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5NE440ABFF000XXX |
| E-Number (Norway) | 4380399 |
| EAN | 8056221004626 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 5.6 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 6.088 kg |
| Package Level 1 EAN | 8056221004626 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1183 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC/DC |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | 24.1 W |
| Rated Current (In) | 400 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 2000…4000 A |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 750 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 2 Poles in Series 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 2 Poles in Series 25 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | TMA |
| Release Type | TM |
| Setting Range | 280…400 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |