View larger
1SDA100373R1 ABB XT5N 630 Ekip M Dip LIU In 500A 3p F F
1SDA100373R1
100373
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for motor protection applications, the 1SDA100373R1 ABB XT5N 630 Ekip M Dip LIU In 500A 3p F F molded case circuit breaker safeguards industrial motor circuits from overloads and phase failures. Such specialized breakers are integrated into motor control centers to ensure dependable operational continuity. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2354
- Environmental Product Declaration - EPD: 9AKK108468A1899
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 59.6 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: c3c13247-2272-487a-81d5-0a8005ab0d0d China
- Simplified SCIP: 3635b35c-f70b-48a4-a34d-3ad57fff6e7f Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT5NE350BLFF000XXX
- E-Number (Norway): 4380264
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | c3c13247-2272-487a-81d5-0a8005ab0d0d China |
| Simplified SCIP | 3635b35c-f70b-48a4-a34d-3ad57fff6e7f Germany |
| 2914d72d-71c7-44cc-8ec2-8599b5cd0384 Bulgaria | |
| 6b0018f9-a32a-4f19-8a86-398c14c120ee Portugal | |
| 80428230-685e-4bf7-8b52-ea9c4743a52a Sweden | |
| d1f2977c-2a1c-4d0a-9395-1b0205576802 France | |
| 3d008c3b-abfc-4275-8825-e2356b476e85 Poland | |
| 504407fb-991c-4896-b10f-ca92a4d152e3 Spain | |
| b4184a7e-2b96-4805-be64-a0d70e19b0a5 Denmark | |
| f69e0438-0218-4ce5-b542-9f7db22ac6e5 Germany | |
| a3cf481f-37ed-41aa-96f5-8a9c6a1d9c6d Belgium | |
| b65cefee-c1c4-4d08-9988-b1234899aefe Germany | |
| 073d3c5e-bed9-4d01-b131-5fa1932b8ce0 Hungary | |
| 69f8ad20-b102-476e-bcd7-f3d02cd83d47 Finland | |
| b194b00e-ae47-447f-842d-db013a3187c2 Poland | |
| f7e8185b-427b-4ab1-b933-dc817ffa21be Croatia | |
| 8a7748f0-7f92-41ba-860d-75b1f86e967b Czech Republic | |
| 8170daf7-a679-42f0-9011-6fdc4237ed8c Sweden | |
| 0232285f-bda7-459e-86cd-da06c1ed523f Poland | |
| dbd58c9d-006d-42a3-8cbd-12df37080e22 Netherlands | |
| f92571e2-97bf-4c44-a3cd-fdb0e4916580 Hungary | |
| e17d70eb-5f18-4ab0-8f2a-a6f8f9d6b798 Germany | |
| 51694cf2-bc4e-40b6-bf82-e7277d91ba93 France | |
| 1b7314bf-cd78-41d2-b065-d03d3013a81e Greece | |
| 55eb3158-a655-4b43-b55f-9bd98af8fd2a Estonia | |
| 87e69f05-fcb1-43b5-ae53-939c415c3844 Norway | |
| 828b3284-32a8-4604-a066-16280764b8a1 Belgium | |
| e403c408-1024-4732-9654-e6c36daf1270 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5NE350BLFF000XXX |
| E-Number (Norway) | 4380264 |
| EAN | 8056221004503 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 4.82 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 5.308 kg |
| Package Level 1 EAN | 8056221004503 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Motor Protection |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1115 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 28.3 W |
| Rated Current (In) | 500 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | Ekip M Dip LIU |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |