View larger
1SDA100372R1 ABB XT5N 400 Ekip M Dip LIU In 400A 3p F F
1SDA100372R1
100372
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A molded case circuit breaker provides essential thermal-magnetic or electronic overcurrent protection for demanding electrical distribution circuits and industrial machinery. Engineers install these components to guard against damaging short circuits and sustained overloads in manufacturing plants. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2354
- Environmental Product Declaration - EPD: 9AKK108468A1899
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 59.6 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 7ccc7b19-4c7d-4159-9426-c80b10ab1658 China
- Simplified SCIP: 2f42c47d-4aa7-455f-8ed2-86ba22be7df6 Croatia
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT5NE340ALFF000XXX
- E-Number (Norway): 4380263
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 7ccc7b19-4c7d-4159-9426-c80b10ab1658 China |
| Simplified SCIP | 2f42c47d-4aa7-455f-8ed2-86ba22be7df6 Croatia |
| 83ccf617-fd1b-4137-baf4-f002b2a73b17 Finland | |
| f71938a4-9818-40dc-95e9-2af557f22d4b Poland | |
| a2862225-706b-4942-815d-60e0957b9b08 Poland | |
| ad1e45e6-f995-4a69-9195-4f4efd2bd31d Czech Republic | |
| 2d8f289f-e0d5-485f-931f-f5f13f43b117 Norway | |
| f3022d31-ad7f-4fb0-8880-8f0f14332ff1 Sweden | |
| c4861b8a-2c3f-44a0-907f-3cdda1a4f5f7 France | |
| f49f22d4-4464-47f7-a30c-9e5cd9c7a828 Germany | |
| bfc30817-70e1-4aa6-8c28-a26918c38ca2 Hungary | |
| d628c1b4-095d-45a0-b612-2d81c22ab5ad Netherlands | |
| 3bfc0ccb-2fd4-4e01-9862-30d530600381 Greece | |
| e9889c7c-1c47-4233-abb6-32578cffdec2 Estonia | |
| 609203fb-ea53-44ab-a092-3fc9b6d19e47 Belgium | |
| fbd015c5-3731-456e-9639-3ca0398aa645 Germany | |
| ab8ab073-83ce-4c39-b75a-8a95c35eef35 Denmark | |
| 2250f3cd-b05f-49dc-916f-91dd7a0a03d6 Spain | |
| 9a92effe-27d6-4dfa-8122-dc3fb2d72682 Hungary | |
| ee5417d7-68a9-4a43-b1ea-65fa55bae684 Belgium | |
| 0809c4ca-0a0a-483f-94ef-1cc2c550e169 Germany | |
| 3cfa9113-88cd-4e35-bca5-202990aa01f2 Germany | |
| fc1a37b6-bfff-41d6-85cb-0947e03f46a4 Germany | |
| 85d5959b-9836-46ae-ad8f-68bf64f78b8d Poland | |
| 8253ade6-53fe-46f3-a2f0-81b78152ab27 Bulgaria | |
| 97da49e1-be36-4181-879a-1e26dbdcecbb Sweden | |
| 716f1d83-9801-4588-8516-5812e3de610b Portugal | |
| daf66853-0650-488a-96aa-721208a2a2ff France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5NE340ALFF000XXX |
| E-Number (Norway) | 4380263 |
| EAN | 8056221004497 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 4.82 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 5.308 kg |
| Package Level 1 EAN | 8056221004497 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Motor Protection |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1115 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 19 W |
| Rated Current (In) | 400 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | Ekip M Dip LIU |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |