View larger
1SDA100361R1
100361
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | bac9665d-a484-4c00-bcd1-34fbeeae2dc6 China |
| Simplified SCIP | fe5ac2f0-151e-4880-934b-580d420cddb5 Germany |
| 4ed7803a-3206-4d80-ae10-cf850567dab8 Sweden | |
| e7a92af8-6c09-4c44-954b-6bbe150e6155 Portugal | |
| aabb617d-9b0d-4a17-9c0a-ea50942cc3df France | |
| 12bf2191-ff5f-43b3-87b5-abd36d791501 Poland | |
| 2f5bad6f-8e9e-4ca3-b80a-d509bcc903c1 Bulgaria | |
| da932cae-c36f-4b8e-b32e-efddc29da4ae Greece | |
| 971d42ed-ebd3-4008-86b2-01d7c8414697 Germany | |
| ffd1b48b-5b37-4f43-813f-93f9184caaba Estonia | |
| d3a8a388-8c33-422f-94a3-d8eafa872d10 Belgium | |
| 08d31908-0626-48a8-b90c-a7125d7d0fe1 France | |
| f8afd5db-3f9d-40b9-b251-269cd1672c1c Denmark | |
| 196cf7f5-1bef-4d23-b2fd-3a31c406e36f Hungary | |
| 976940d8-5960-46e5-b771-f62c79f39035 Spain | |
| 186bd4e7-33c3-4e0c-bd2d-77f2cbcd6b4b Germany | |
| 807dad46-16af-4af2-9e93-c0401142936c Sweden | |
| 26c9cff6-560d-4ac9-9548-c2e4c2f8e9a2 Norway | |
| 24c0b0da-b256-4077-b570-adddaa0f2fc7 Czech Republic | |
| 8e9c35cb-bbaa-4473-b26e-908d267c4dbf Croatia | |
| 825bef3a-6c1d-4566-8d68-f09aaa096856 Poland | |
| 07ee6d36-758e-4f43-abc3-22ab3209a26b Finland | |
| bb5cf597-137c-4c18-bfde-e3cfa4ecfd1e Netherlands | |
| 991365a7-cce1-4059-aaa7-d16d34f1c9b3 Poland | |
| 0561b12f-188b-4519-ae7b-b775975c7e81 Germany | |
| 36c0583c-7d3a-4d90-ad6c-650dff8da29d Hungary | |
| a03bab29-dd97-4256-a48b-29b09ba1339e Germany | |
| 5c56589a-b64d-4ae4-87e1-2758b644cb78 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5NE332AGFF000XXX |
| EAN | 8056221004381 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 4.82 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 5.308 kg |
| Package Level 1 EAN | 8056221004381 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1115 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 11.6 W |
| Rated Current (In) | 320 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 70 kA |
| (230 V AC) 70 kA | |
| (240 V AC) 70 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 25 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 20 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 320 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 128.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 320 A |
| Adjustment range undelayed short-circuit release (EF007131) | 320 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |