View larger
1SDA068316R1 ABB XT4S160 TMD R32 Im320 4P F F
1SDA068316R1
068316
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb part number 1SDA068316R1 is an advanced industrial circuit-breaker engineered to interrupt fault currents and protect four-pole power distribution systems. Thermomagnetic release mechanisms inside such units react swiftly to overloads and short circuits. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Abb
- Manufacturer part number: 1SDA068316R1
- Catalogue code: 068316
- Catalogue title: 1SDA068316R1 ABB XT4S160 TMD R32 Im320 4P F F
- Manufacturer summary: XT4S160 TMD R32 Im320 4P F F C.BREAKER TMAX XT4S 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 32-320 A
More info
▲b'
General Information
XT4S 160 TMD 32-320 4p F F
1SDA068316R1
8015644022228
XT4S 160 TMD 32-320 4p F F
C.BREAKER TMAX XT4S 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 32-320 A
Ordering
8015644022228
1 piece
85362090
Dimensions
140 mm
160 mm
82.5 mm
3.05 kg
Container Information
1 piece
145 mm
210 mm
168 mm
3.5 kg
8015644022228
Environmental
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Additional Information
Power Distribution
AC/DC
120 cycles per hour
8000 cycle
Nr. Operations 240 cycles per hour
Nr. Operations 25000 cycle
4
CB with SOR 15 ms
CB with UVR 15 ms
1 piece
at Rated Operating Conditions per Pole 4.44 W
SACE Tmax XT
Moulded Case Circuit Breaker
CB
32 A
50 / 60 Hz
690 V
8 kV
320 A
1000 V
690 V AC
500 V DC
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
160 A
TMD
TM
22.4...32 A
S
IEC
XT4
Fixed Circuit-Breakers
F
Certificates and Declarations (Document Number)
Classifications
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
EC000228 - Power circuit-breaker for trafo/generator/installation protection