An Abb 1SDA068123R1 ABB XT4N160 Ekip LS/I R63 3P F F is an electronic trip circuit breaker applied in power distribution systems to isolate faulty circuits and protect connected equipment. It offers precise electronic monitoring capabilities for industrial switchboards. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 56.30 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2352
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108469A1858
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: c0653574-c1b3-4068-a27f-6c7e18366db9 Italy (IT)
- Simplified SCIP: e39dfd6b-5201-4988-98d1-76e3fffb12e9 Czech Republic (CZ)
- Order Code US and Canada: XT4NE3063EFF000XXX
- EAN: 8015644020002
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2352 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1858 |
| 9AKK108468A1898 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | c0653574-c1b3-4068-a27f-6c7e18366db9 Italy (IT) |
| Simplified SCIP | e39dfd6b-5201-4988-98d1-76e3fffb12e9 Czech Republic (CZ) |
| a5ff0751-f82a-42f4-9bf9-ad023af20fa6 Portugal (PT) | |
| eeac31c7-f70d-47f4-a5ae-218d084430ee Croatia (HR) | |
| aba0bbfe-33f5-4993-888b-5dd2700bff76 Germany (DE) | |
| 2e6fea93-d568-484f-be11-020079aae891 Germany (DE) | |
| 4d691313-376f-4808-93ad-dda1afcd44b4 Germany (DE) | |
| cf7be5f5-fe3f-4af1-a856-35864dbb47df France (FR) | |
| 8d859e3e-3ded-4b4f-8944-7839572220f8 Sweden (SE) | |
| bf66ba17-011e-4a7c-bfad-3163718380b6 Denmark (DK) | |
| fd496bc7-4406-4b5f-984e-0d1404fa7111 Germany (DE) | |
| 840007a2-801d-4144-8a85-a4b06e48cbf7 Hungary (HU) | |
| 7a7de385-68a8-457b-820f-2b40c5df2c32 France (FR) | |
| 1501bc97-00e8-478a-b554-2b69c9e25c56 Spain (ES) | |
| a2b26b29-0a5f-40c8-8b3d-0176695eba24 Belgium (BE) | |
| a92a314b-e296-4dab-a654-f0cd7f18b35b Estonia (EE) | |
| f33fed28-2ed5-4445-afb4-8209f2355dce Poland (PL) | |
| b0d4244a-1ab7-4355-a780-4270de2870c7 Hungary (HU) | |
| c925d791-f489-420f-b460-3dcc050016dd Greece (GR) | |
| 6314f4d3-8c2c-4b39-8e7e-7e6fbe8a9e24 Poland (PL) | |
| b0e6bdd0-e8b2-401c-9810-61592b785bb0 Poland (PL) | |
| 3ad7f0de-b227-4777-8d97-886b42c005bc Belgium (BE) | |
| a453d701-463a-426c-9af8-3d10a1f57584 Germany (DE) | |
| a569b1c1-c44b-4074-bd0d-0e1313124b09 Finland (FI) | |
| 2f173b3e-244e-4cd5-acf4-4da9b259b900 Bulgaria (BG) | |
| f0b87ecc-baa0-4bd5-a0c4-e54d4a46960b Netherlands (NL) | |
| 9fc6da40-0525-4c4a-9c57-4771cdf8c56d Sweden (SE) | |
| b499ffd3-088a-4942-9fe3-01ae07d3b794 Norway (NO) | |
| Ordering | |
| Order Code US and Canada | XT4NE3063EFF000XXX |
| EAN | 8015644020002 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 2.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 145 mm |
| Package Level 1 Height | 210 mm |
| Package Level 1 Depth / Length | 168 mm |
| Package Level 1 Gross Weight | 2.5 kg |
| Package Level 1 EAN | 8015644020002 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 85..200 mm² |
| Current Type | AC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 1.4 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 63 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M8 |
| Release | Ekip Dip LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1003 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000722R0100 |
| Mechanical Drawings | 1SDH000722R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000722R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |