View larger
1SDA068089R1 ABB XT4N160 TMA R160 Im1600 3P F F
1SDA068089R1
068089
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb 1SDA068089R1 circuit-breaker provides vital fault protection by automatically cutting off power when current exceeds safe operating thresholds in industrial setups. Maintenance engineers incorporate these reliable components into machinery control cabinets and distribution panels to prevent electrical hazards.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2351
- Environmental Product Declaration - EPD: 9AKK108469A1857
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 56.30 %
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 745b6d39-8f0d-4ac6-bc4a-6fac086c16e7 Italy
- Simplified SCIP: 7f5e9447-0def-454a-b273-99aacc9f91d5 Belgium
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT4NE3160BFF000XXX
- E-Number (Norway): 4379854
- EAN: 8015644019822
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2351 |
| Environmental Product Declaration - EPD | 9AKK108469A1857 |
| 9AKK108468A1892 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 745b6d39-8f0d-4ac6-bc4a-6fac086c16e7 Italy |
| Simplified SCIP | 7f5e9447-0def-454a-b273-99aacc9f91d5 Belgium |
| 8035855e-1693-4925-ad10-1a2fc1f3a256 France | |
| 54606708-badf-40e7-9011-e0f4c6a16046 Spain | |
| 9998efdd-c533-42b9-81e8-d4fa12ffa691 Hungary | |
| 413955b3-62ca-480b-8d35-e5577e67ee3c Czech Republic | |
| 335347cb-4e9e-4bc7-8532-bba289754638 Germany | |
| ba53fb9e-96a2-41e8-b402-0a7964dfc568 Croatia | |
| 22e39f6a-9279-4c5b-a636-7c154e35f61c Germany | |
| 39cf5c34-fbf4-4beb-a445-182605e622d0 Germany | |
| 17152744-f5af-47c9-b2ce-0550b01a3247 Sweden | |
| d6c22644-e041-4dc0-9284-9bdf262a4813 Germany | |
| 8ba92875-ee47-497b-ab27-a01edad2efac Norway | |
| 43b7b3bd-24f3-4611-9221-86c1f2ba9ab4 Poland | |
| 60997a29-72e7-4ce1-8e41-9a9f64712aa4 Bulgaria | |
| 59629924-f0dc-4d5a-b876-acc94e10f515 Poland | |
| 55418ea7-cf8f-4608-9e84-811f1f1ba510 Netherlands | |
| 99a74fe6-4915-4af7-8921-3e2e945a1bb2 Sweden | |
| 5f25017d-f803-4c68-aac8-910da62b517e Finland | |
| 16e2623d-fe6a-4948-ace5-a55f7d857999 Hungary | |
| 085dcb90-66a4-47f7-8da1-8aa118aefedb Poland | |
| 6e402778-43cd-48ff-bcb0-b6fc5a332718 Denmark | |
| 2860ea47-b0fe-465b-8951-163d15465168 France | |
| 874de171-f8ed-4993-8e09-fcb6d9e49f8d Greece | |
| 164b1aef-ac46-49fb-8819-90240e0807c0 Portugal | |
| b5d97084-8eb5-47a4-91ef-de174eab3bbf Germany | |
| 2d4b6a55-466b-4086-a813-b650137e5972 Belgium | |
| 4875e291-4f4b-419a-9d7c-ad0d18b5807c Estonia | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT4NE3160BFF000XXX |
| E-Number (Norway) | 4379854 |
| EAN | 8015644019822 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 2.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 145 mm |
| Package Level 1 Height | 210 mm |
| Package Level 1 Depth / Length | 168 mm |
| Package Level 1 Gross Weight | 2.5 kg |
| Package Level 1 EAN | 8015644019822 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1003 |
| Technical | |
| Connecting Capacity Main Circuit | Busbar 85..200 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 8.88 W |
| Rated Current (In) | 160 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 800…1600 A |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 750 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M8 |
| Release | TMA |
| Release Type | TM |
| Setting Range | 112...160 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000722R0100 |
| Mechanical Drawings | 1SDH000722R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000722R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |