View larger
1SDA068056R1 ABB XT3N250 TMD R125 Im1250 3P F F
1SDA068056R1
068056
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SDA068056R1 is a molded case circuit breaker engineered to protect electrical circuits against overcurrents and short-circuit faults in industrial environments. Such components help prevent electrical fires and equipment damage by interrupting dangerous current surges. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 56.6 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2350
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108468A2294
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 060c77d0-4139-433d-8c4f-d88fed44fc2e Italy (IT)
- Simplified SCIP: 45b855f8-b376-4f76-b2bc-39edd8f0d14b Germany (DE)
- Order Code US and Canada: XT3NE3125AFF000XXX
- EAN: 8015644019273
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.6 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2350 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A2294 |
| 9AKK108468A7794 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 060c77d0-4139-433d-8c4f-d88fed44fc2e Italy (IT) |
| Simplified SCIP | 45b855f8-b376-4f76-b2bc-39edd8f0d14b Germany (DE) |
| 4cbaf6e3-a5eb-489d-87ef-be4d181bba1f Germany (DE) | |
| f4813ee8-4bd9-4710-8ff1-8d585c08669f Sweden (SE) | |
| 6af48308-c890-4b2f-ad9e-0afa20ced15f Germany (DE) | |
| 126e5ef6-17ae-46de-a9b7-9c1853c29cdf Croatia (HR) | |
| 15f21779-11f3-4f57-92e9-f37f6483083e Poland (PL) | |
| 7b480bd1-c869-4c52-bea3-4a19080c72ed Norway (NO) | |
| 25c5d0c6-03f0-4059-bf42-b4378710a580 Finland (FI) | |
| 64a714a6-7109-48df-a95b-492398066c81 Netherlands (NL) | |
| 26082a9a-c241-4d79-932e-0e7c89c4e58b Germany (DE) | |
| 1b1be860-0d28-498d-b281-1b2ce33735d8 Netherlands (NL) | |
| 167dbb7e-a9f8-4490-a102-6c4dd7c1b630 Czech Republic (CZ) | |
| 6f5df75c-cad7-4d20-b825-45766f246b0d Poland (PL) | |
| a4d437ea-7592-46d1-bd07-7a63e34a6e4b Poland (PL) | |
| ff6419d3-fd83-41cf-ad8d-e5381c63e5ec France (FR) | |
| 025d5208-4f7c-4312-a9a3-743c2d22343a Germany (DE) | |
| 983587e3-b4cf-4f62-82e6-3ae9c503a14d Netherlands (NL) | |
| beeb293b-bedc-486d-9f3f-a661b1df9ff5 Estonia (EE) | |
| 03cc8dc5-f6aa-43b2-9bb7-0c2f98dd2546 Greece (GR) | |
| c62f0a68-0fd8-4064-9775-b15cd3ca285d Portugal (PT) | |
| a535e04b-4062-4c86-a26d-84fbd430ddd9 Bulgaria (BG) | |
| 3f53a480-95b2-4557-8dfe-27ac194e8d36 Sweden (SE) | |
| 0bbb0b9d-f39f-460a-bdb6-f315bfb6e89c Denmark (DK) | |
| 5054a3ed-3e76-43c2-8f4e-8aa9338abba4 France (FR) | |
| cafb9e83-2c21-4eb9-8fe2-1f91ff9cc802 Netherlands (NL) | |
| 6ce247f6-29d5-45a3-bb60-66f86d971b82 Spain (ES) | |
| 75002095-85e4-4711-8c65-cecf9b6bd794 Netherlands (NL) | |
| Ordering | |
| Order Code US and Canada | XT3NE3125AFF000XXX |
| EAN | 8015644019273 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 150 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 155 mm |
| Package Level 1 Height | 190 mm |
| Package Level 1 Depth / Length | 155 mm |
| Package Level 1 Gross Weight | 1.716 kg |
| Package Level 1 EAN | 8015644019273 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 85..192 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 6.6 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Leistungsschalter |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 125 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 1250 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (240 V AC) 50 kA | |
| (380 V AC) 27 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 19 kA | |
| (500 V AC) 15 kA | |
| (525 V AC) 9.75 kA | |
| (690 V AC) 3.75 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (240 V AC) 50 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 20 kA | |
| (525 V AC) 13 kA | |
| (690 V AC) 5 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 50 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Recommended Screw Driver | Main Circuit M8 |
| Release | TMD |
| Release Type | TM |
| Setting Range | 87.5...125 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT3 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0409 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5530 |
| GL Certificate | 1SDL000163R0094 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000720R0100 |
| Mechanical Drawings | 1SDH000720R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000720R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |