View larger
1SDA068054R1 ABB XT3N250 TMD R80 Im800 3P F F
1SDA068054R1
068054
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB XT3N250 TMD R80 Im800 3P F F molded case circuit breaker defends electrical networks against thermal overloads and instantaneous short circuits. Equipment of this class is standard in power distribution panels to protect cabling and machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 56.6 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2350
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108468A2294
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 2daf31b9-2348-4a6e-9e8a-81124dff1f66 Italy (IT)
- Simplified SCIP: 9a320fd7-0b82-4013-a485-797e8f3b59b5 Germany (DE)
- Order Code US and Canada: XT3NE3080AFF000XXX
- E-Number (Finland): 3641003
- EAN: 8015644019259
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.6 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2350 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A2294 |
| 9AKK108468A7794 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 2daf31b9-2348-4a6e-9e8a-81124dff1f66 Italy (IT) |
| Simplified SCIP | 9a320fd7-0b82-4013-a485-797e8f3b59b5 Germany (DE) |
| 22758885-a58f-423d-937c-09224f9cfefe Czech Republic (CZ) | |
| 797e41cf-fdd1-4e5e-ad97-d5bae67c8546 Croatia (HR) | |
| b77f98fe-cc15-490e-87f4-4e0b89bef97b Germany (DE) | |
| f028c2cb-6906-469a-9f2c-767993877952 Germany (DE) | |
| 7c5520c8-d359-4cc1-9b26-a55004253c97 Sweden (SE) | |
| 935ad0ae-6ec0-404c-8f2d-313f2a4df53e Hungary (HU) | |
| f301d62f-2277-49f0-8d77-6666b65972a3 Spain (ES) | |
| 2e5b1973-4693-44e2-83a8-5e6737da54e2 France (FR) | |
| 3aa7b829-b277-4653-97e9-5ac332d42fb4 Belgium (BE) | |
| b90a9ce8-ff7d-427b-8c89-397317c23995 Poland (PL) | |
| 024acfd6-6efc-472e-89d3-dd8161e3fc11 Bulgaria (BG) | |
| 5430309d-7d0f-40a1-8c6b-1b231238aea1 Poland (PL) | |
| e7db486f-35f8-4128-9669-92070d69c1c3 Germany (DE) | |
| 7e1f0c7d-a44d-4438-bf17-ec7050202a47 Hungary (HU) | |
| ed81ec30-0106-489a-9ab2-b86b9ef17487 Poland (PL) | |
| 89d9f877-1b3d-44f8-af52-e9f95d254eb3 Finland (FI) | |
| 01545809-dca8-4b9b-8fef-34c2b259ff81 Netherlands (NL) | |
| 2a656703-c838-4634-9749-75298d82f595 Norway (NO) | |
| a478e21a-65db-41b9-8abe-be939c0df2c6 Sweden (SE) | |
| 8e65be0d-93c6-4afa-8955-9d2357749af2 Belgium (BE) | |
| 03820ef0-92a6-400b-83d5-a63d3040619d Estonia (EE) | |
| b90786ba-3bc1-4e81-a423-9dfe1cd24f8d Greece (GR) | |
| ec7c1142-981f-4500-8d93-a342f73ece8d France (FR) | |
| 977522f5-cc5d-48fb-b2e8-b5f1141bda78 Portugal (PT) | |
| 06287fee-bec2-4a5f-b858-82fb4e6e72e3 Germany (DE) | |
| f59d716c-8fb5-4c70-a1f3-259bd6700a17 Denmark (DK) | |
| Ordering | |
| Order Code US and Canada | XT3NE3080AFF000XXX |
| E-Number (Finland) | 3641003 |
| EAN | 8015644019259 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 150 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 155 mm |
| Package Level 1 Height | 190 mm |
| Package Level 1 Depth / Length | 155 mm |
| Package Level 1 Gross Weight | 1.7 kg |
| Package Level 1 EAN | 8015644019259 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 85..192 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 4.8 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 80 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 800 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (240 V AC) 50 kA | |
| (380 V AC) 27 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 19 kA | |
| (500 V AC) 15 kA | |
| (525 V AC) 9.75 kA | |
| (690 V AC) 3.75 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (240 V AC) 50 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 20 kA | |
| (525 V AC) 13 kA | |
| (690 V AC) 5 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 50 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Recommended Screw Driver | Main Circuit M8 |
| Release | TMD |
| Release Type | TM |
| Setting Range | 56...80 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT3 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0409 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5530 |
| GL Certificate | 1SDL000163R0094 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000720R0100 |
| Mechanical Drawings | 1SDH000720R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000720R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |