View larger
1SDA067772R1
067772
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2348 |
| Environmental Product Declaration - EPD | 9AKK108469A1856 |
| 9AKK108468A1891 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 55.70 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 1dc6a310-6934-476b-ae7a-01b553ee10d7 Italy |
| Simplified SCIP | 16648667-86fa-452e-bbaa-2cce5d4c0503 Germany |
| 3cd79016-6880-4817-b905-22b27da51a7b Norway | |
| ce5c0b30-b450-41f7-9e3c-f797fbcc4e0f Finland | |
| 8138b894-2275-4f75-aea0-788692633ae4 Netherlands | |
| 167fbffc-d583-4678-80fb-f2a3f561bb55 Germany | |
| 7e27380c-1124-4757-b1ca-3dc6ee0e0167 Denmark | |
| 0d83fee6-422d-4f7d-aab7-a270475a6133 Netherlands | |
| 5074dc7d-a027-4bf1-ab29-79cdad30e2ba Estonia | |
| 3048c939-bebd-4f89-b699-405f936911b6 Greece | |
| 50ae6e64-aba8-43ff-9b0c-012c6c825b45 Portugal | |
| 3767c8b5-41e3-4344-9088-63cd289d917d Germany | |
| 3d89592a-4b88-44b7-bd10-b42d18bdf22b Croatia | |
| 9f3ae016-d11f-4123-9fcf-947a068b61e8 Czech Republic | |
| 02f02af5-313a-47d7-ad3a-969e3a297b73 Poland | |
| d5d65095-176f-4371-a94d-70965c023fa0 Netherlands | |
| fe926dee-797c-4de9-93f9-35eaf8cdbe1b Germany | |
| 7fbfff19-137f-4d24-a55c-9dec628964e2 Germany | |
| e759723d-3556-44b3-97f5-a710ad318838 France | |
| 9f058dfd-37cf-4f41-ac3b-a7ae82ff9608 Netherlands | |
| c920c74b-4e01-4252-892e-d792ad087a04 Spain | |
| efea1de7-c2e5-4722-b76e-34c1b59020ee Netherlands | |
| f7262375-560e-4dd3-ab4f-c18e65fc8701 Bulgaria | |
| 1fb7e3d4-acea-4ca2-bdfd-e196e300615a Sweden | |
| af855937-55e1-4436-84bd-87d3ead6da3f Poland | |
| e979ace9-8c22-4611-9f6b-a6030833163c France | |
| e64c283b-002a-458b-95dc-fc12ca10ec9a Sweden | |
| 35783688-f423-4221-9dd6-59acceded38f Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT2HE3004IFF000XXX |
| E-Number (Norway) | 4379384 |
| EAN | 8015644016685 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 90 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 131 mm |
| Package Level 1 Height | 212 mm |
| Package Level 1 Depth / Length | 147 mm |
| Package Level 1 Gross Weight | 1.2 kg |
| Package Level 1 EAN | 8015644016685 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Motor Protection |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1001 |
| Technical | |
| Connecting Capacity Main Circuit | Busbar 32.5..100 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 2.47 W |
| Rated Current (In) | 4 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 56 A |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M6 |
| Release | MF |
| Release Type | M |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT2 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5901 |
| GL Certificate | 1SDL000163R0093 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000721R0100 |
| Mechanical Drawings | 1SDH000721R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000721R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers |
| Object Classification Code | Q |
| UNSPSC | 39121616 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |