An Abb molded case circuit breaker provides reliable overcurrent and short-circuit protection for commercial and industrial electrical distribution systems. Technicians install these units in switchboards to automatically disconnect faulted circuits and prevent equipment damage. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Abb
- Manufacturer part number: 1SDA067751R1
- Catalogue code: 067751
More info
▲b'
General Information
XT2S 160 TMG 25-160 4p F F
1SDA067751R1
8015644016470
XT2S 160 TMG 25-160 4p F F
C.BREAKER TMAX XT2S 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMG R 25-160 A
Ordering
8015644016470
1 piece
85362090
Dimensions
120 mm
130 mm
82.5 mm
1.45 kg
Container Information
1 piece
130 mm
208 mm
145 mm
1.55 kg
8015644016470
Environmental
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Additional Information
Generator Protection
AC/DC
120 cycles per hour
8000 cycle
Nr. Operations 240 cycles per hour
Nr. Operations 25000 cycle
4
CB with SOR 15 ms
CB with UVR 15 ms
1 piece
SACE Tmax XT
Moulded Case Circuit Breaker
CB
25 A
50 / 60 Hz
690 V
8 kV
160 A
1000 V
690 V AC
500 V DC
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
160 A
TMG
TM
17.5...25 A
S
IEC
XT2
Fixed Circuit-Breakers
F
Certificates and Declarations (Document Number)
Classifications
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)