View larger
1SDA067737R1 ABB XT2N160 TMG R160 Im480 4P F F
1SDA067737R1
067737
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An 1SDA067737R1 ABB XT2N160 TMG R160 Im480 4P F F is a thermal-magnetic molded case circuit breaker designed to provide dependable overload and short-circuit protection for electrical installations. Industrial automation panels and commercial distribution systems use these four-pole breakers to isolate faults and protect sensitive machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 55.70 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2348
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108469A1856
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 8823c627-2b82-4af3-b94c-16b0343030f3 Italy (IT)
- Simplified SCIP: 628a31b8-1c60-4ef0-8ac9-d6215df80af6 Germany (DE)
- Order Code US and Canada: XT2NE4160NFF000XXX
- EAN: 8015644016333
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.70 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2348 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1856 |
| 9AKK108468A1891 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 8823c627-2b82-4af3-b94c-16b0343030f3 Italy (IT) |
| Simplified SCIP | 628a31b8-1c60-4ef0-8ac9-d6215df80af6 Germany (DE) |
| c9c3664b-801d-4034-9aca-39fe841cd0d6 Czech Republic (CZ) | |
| 21fa2375-9b73-45a6-93a9-ad2dde9d2325 Germany (DE) | |
| 5448ecc4-e39b-4ec6-935d-6cc36a3f74b0 Sweden (SE) | |
| 27121463-e4b2-4069-9480-a568ccbd4e9d Denmark (DK) | |
| 0ba77584-e336-4769-8663-2fdeb6050524 Portugal (PT) | |
| 1bc69f01-9de8-491d-b544-3494ec07ea9a Germany (DE) | |
| 609b2963-90f7-4f17-863f-687ce4b8a690 Croatia (HR) | |
| 3605a08f-7384-4fa0-8d99-b717760098cc Hungary (HU) | |
| 785bb4a3-bee8-4adf-bcb6-2ef507c1af10 Spain (ES) | |
| a15a398c-cc36-4d1f-9ff8-3f2ce52aea85 Belgium (BE) | |
| 80945423-83d1-45e9-b2b8-300885250f03 Poland (PL) | |
| 54cc1d8d-9a7c-42c0-a7c6-13633a43f75e Poland (PL) | |
| 2f4be063-bc56-40e2-859b-dc642fdbacfe Netherlands (NL) | |
| 41122fd6-a33a-4950-85e7-f27ac3322c30 Norway (NO) | |
| 7387a2e4-253e-45da-be5c-bc29f48df18f Sweden (SE) | |
| 865d572a-b649-432e-9870-8b5789e1dd43 Bulgaria (BG) | |
| 733a732a-df0f-458b-b25c-2141f8366278 France (FR) | |
| 42154e14-6e82-422a-84ef-766f0c431b19 Germany (DE) | |
| a0d0c164-658d-4a3b-8edc-76e2be211a6b France (FR) | |
| 6a99099b-d0ef-4ddd-975a-f6a41daab650 Greece (GR) | |
| ad2072ff-80f3-4207-b67d-3674570c8640 Germany (DE) | |
| edab0bdc-02a8-4ae0-afb6-9ab8d17e241b Belgium (BE) | |
| ee501b47-7e12-4e0e-81e0-8bad446036a1 Estonia (EE) | |
| 38533098-9f9e-4b7b-aad7-8f5f754df470 Hungary (HU) | |
| f4f149fd-5db1-4345-a3d3-0aa2886a6623 Poland (PL) | |
| 318f5f6e-5f40-4265-8130-6919d1803aa7 Finland (FI) | |
| Ordering | |
| Order Code US and Canada | XT2NE4160NFF000XXX |
| EAN | 8015644016333 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 120 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.6 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 130 mm |
| Package Level 1 Height | 208 mm |
| Package Level 1 Depth / Length | 145 mm |
| Package Level 1 Gross Weight | 2.112 kg |
| Package Level 1 EAN | 8015644016333 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Generator Protection |
| Connecting Capacity Main Circuit | Busbar 32.5..100 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 4 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 16.15 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 160 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 480 A |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 36 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMG |
| Release Type | TM |
| Setting Range | 112...160 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT2 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1002 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5901 |
| GL Certificate | 1SDL000163R0093 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000721R0100 |
| Mechanical Drawings | 1SDH000721R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000721R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |