View larger
1SDA067593R1 ABB XT2H160 TMD R12.5 Im125 3P F F
1SDA067593R1
067593
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 1SDA067593R1 ABB XT2H160 TMD R12.5 Im125 3P F F molded case circuit breaker delivers precise thermal-magnetic protection for demanding industrial circuits. Such components are typically deployed inside electrical panels to isolate faults and protect machinery from severe overcurrent situations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 55.70 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2348
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108469A1856
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 6ef02f8d-44d7-4a1d-85c0-bb5509f53cf1 Italy (IT)
- Simplified SCIP: 3683613d-61ef-4311-bd97-7eeac591c35b Germany (DE)
- Order Code US and Canada: XT2HE3013AFF000XXX
- EAN: 8015644014896
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.70 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2348 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1856 |
| 9AKK108468A1891 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 6ef02f8d-44d7-4a1d-85c0-bb5509f53cf1 Italy (IT) |
| Simplified SCIP | 3683613d-61ef-4311-bd97-7eeac591c35b Germany (DE) |
| 940d1827-474e-407d-82ef-d9526848d051 Sweden (SE) | |
| 984ef8a3-ece6-4420-ad3e-936bc479f67e Poland (PL) | |
| 7147f31a-3dd4-4342-a2ab-bb704fffc53d France (FR) | |
| 72b319fd-48e3-4d39-bcae-9e16277d20a7 Sweden (SE) | |
| 211d7250-c198-476b-ba75-e0c9cf4b0040 Poland (PL) | |
| fbb83dae-37fb-46a2-b0f7-1d143814451d Germany (DE) | |
| 6d2894d3-08e1-4f5d-a8a6-df20a66f5e7a France (FR) | |
| 090a44ff-a567-41e4-979f-1f83141daab6 Netherlands (NL) | |
| ff302c37-eb4e-4e05-a8e6-d7318392e68a Spain (ES) | |
| eaf40900-4ad5-4242-8a43-c76a3bfff928 Netherlands (NL) | |
| 4a424d8e-8625-4216-b14c-594d8f212917 Bulgaria (BG) | |
| 5fa9c084-d5d1-4e17-a794-9c7d71470bc6 Norway (NO) | |
| eb0f35df-eb40-48e7-8b80-1e6f82a6018c Finland (FI) | |
| d00d21eb-4bc4-4f0e-9f99-651a21e29eb5 Netherlands (NL) | |
| a6543064-dcd8-42c8-bed2-d14d8feefc67 Germany (DE) | |
| 0b51511e-3e45-41a4-8081-3df847fd42a2 Denmark (DK) | |
| 2fab6abc-dbcc-4da4-a1d2-b0cafaea4832 Netherlands (NL) | |
| 7f7b3c78-b246-4ca1-9ed8-163d895aa242 Netherlands (NL) | |
| 75a9654c-0192-4a7e-9064-d3f5457be6dc Estonia (EE) | |
| 2a77e16b-387e-4d11-9854-5c4bd56d5907 Greece (GR) | |
| a131d7c6-1809-473e-9bce-7a9ba963040f Portugal (PT) | |
| 194c878e-e241-4878-964b-ee7933095491 Germany (DE) | |
| 3d319e43-b151-4a91-ad1e-7c9d39e6eea1 Croatia (HR) | |
| 80e02284-94ce-43e3-9de4-d09d9f891fc0 Czech Republic (CZ) | |
| c43cd84c-b24d-4e73-b307-71d159f63dd5 Poland (PL) | |
| e198ffff-9a2c-402f-93a8-9947c0666c22 Germany (DE) | |
| Ordering | |
| Order Code US and Canada | XT2HE3013AFF000XXX |
| EAN | 8015644014896 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 90 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 131 mm |
| Package Level 1 Height | 212 mm |
| Package Level 1 Depth / Length | 147 mm |
| Package Level 1 Gross Weight | 1.2 kg |
| Package Level 1 EAN | 8015644014896 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 32.5..100 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 1.05 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 12.5 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 125 A |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 15 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 3 Poles in Series 70 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMD |
| Release Type | TM |
| Setting Range | 8.75...12.5 A |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT2 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1001 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5901 |
| GL Certificate | 1SDL000163R0093 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000721R0100 |
| Mechanical Drawings | 1SDH000721R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000721R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |