An Abb air circuit breaker, such as the E3H2000 PR122/P LI 3P F HR (part number 1SDA056435R1), is designed to protect industrial power distribution systems and high-capacity electrical grids from severe overloads and short-circuit faults. These high-performance switching devices are frequently specified for heavy industrial plants, substations, and major electrical rooms.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: 5ab0fc57-672c-4ecc-8f4c-94884ed695b7 Italy
- Simplified SCIP: b92b6abc-4d1e-4eeb-9d3b-53f864b58675 Denmark
- Environmental Information: 9AKK10103A6076
- EAN: 8015644577759
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 404 mm
- Product Net Height: 418 mm
- Product Net Depth / Length: 302 mm
- Product Net Weight: 60 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 5ab0fc57-672c-4ecc-8f4c-94884ed695b7 Italy |
| Simplified SCIP | b92b6abc-4d1e-4eeb-9d3b-53f864b58675 Denmark |
| 937b1de5-ecd7-4edd-a4da-3a212e308114 Belgium | |
| 00056e76-2615-4d15-8e77-423f666bb1c2 Finland | |
| 74450921-ce68-49f0-af17-180e00ff8fbb Germany | |
| 4958fc31-bd36-4de6-b034-0e087ee9348d Sweden | |
| 6b3a3a9b-d9a6-4857-9fd2-d0a9e8a701ca Poland | |
| 6a05dcac-c92c-41b6-ac03-404b2340b563 Spain | |
| 1f5ddbb6-cd67-4614-9957-568875442033 Belgium | |
| b4be6d1d-4840-4e1f-b399-00ca13a38106 France | |
| 7fc48003-fdfb-402d-a569-00ac780a8a4e Germany | |
| 7c2f889f-e420-4489-9619-39bd22277e3c Norway | |
| 1fb9a527-a5cb-46b1-bab0-8e7adba1e7e8 Poland | |
| 31c5349f-444a-4e80-9f65-c42e9e8b9c4d Netherlands | |
| 8e45c6f1-ae11-4987-9b4d-f87e876bb652 Germany | |
| 0c3bab3c-3ef2-4f59-bf12-dfdfe6aafa92 Bulgaria | |
| 7cfbd839-6480-42d3-9ad4-bbb7885e6dea Portugal | |
| 99e8d08f-f40c-4629-9bbd-656690c8425b Greece | |
| 1923f9b7-8f18-461c-ae42-4b7d1375e3bd Croatia | |
| 5b0b7257-d381-4e73-a6f3-e9a6ee94850a Czech Republic | |
| 195e2e4c-3ec4-4bfb-93ce-55defbad93b4 Poland | |
| 5e5ad8ec-2ad8-4bcc-b6d5-d4559686c7d6 Germany | |
| 6dc8ecb3-2c8c-437a-b050-5941f5990ac0 Germany | |
| 85ec4a5b-a148-4709-a3c1-5182c8d7dce7 Sweden | |
| 36551d5a-2fab-4d10-a8da-c079e65043bc Hungary | |
| 4d24e71f-a563-4919-bac7-e2fba68ca0ef France | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644577759 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 404 mm |
| Product Net Height | 418 mm |
| Product Net Depth / Length | 302 mm |
| Product Net Weight | 60 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 72 kg |
| Package Level 1 EAN | 8015644577759 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 9000 cycle |
| Ue = 500 ... 690 V 9000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 130 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 2000 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Rear flat Horizontal | |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |