View larger
1SCA022772R8210
022772
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| End Of Life Disassembling Instructions | 1SCC303050M0201 |
| Environmental Information | 1SCC303050D0201 |
| Environmental Product Declaration - EPD | 1SCC303082D0201 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SCC011021D0201 |
| RoHS Declaration | 1SCC011020D0201 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | bd782dc7-559d-47a6-9a6b-12d315ae8cc0 Finland |
| Simplified SCIP | 71b43f14-0194-4422-bcf3-e528d7558676 Germany |
| b64afbcb-bfd7-4bf5-a073-ca1edd7b4532 Belgium | |
| af563d98-94f9-44aa-ab83-1d5e1f2308ba Italy | |
| 04de584f-936f-4e19-bdf8-cb2ae3db37a6 Poland | |
| fe746273-03cd-4809-bd26-9c7ace7486c1 Hungary | |
| eeaed6c5-a74d-4111-adc4-5b0baca2c117 Portugal | |
| 3251e00d-f108-469d-af6c-963662da3ed4 Denmark | |
| 0edbbe19-58c1-4933-8307-8c6b59debcec Croatia | |
| 7f100c12-24db-4f64-9f96-c701a3e504aa Spain | |
| 65b480a3-b467-4f44-9ed9-2f0e460bc224 Germany | |
| 8b1829dc-e00e-4353-8e78-38e287f089e2 Germany | |
| 0cfc459b-7d5b-48f9-b341-bee2abab576f France | |
| 693fa5ee-b4fa-43c4-ae84-11e09e79f489 Germany | |
| fad282e9-c596-4126-8b72-6ea1295bae9e Norway | |
| 95e7cc8c-de2b-4af0-8833-263fe80884dd Bulgaria | |
| ed774fa5-ca2f-4ef4-a014-116788a1ffb1 Hungary | |
| f0b15fdd-0da9-4568-b6ce-629ff4eb4b04 Germany | |
| d13ec0cf-3358-4498-a1f8-daa316070a79 Netherlands | |
| 8f8cf3a8-b30b-4c5d-a622-af2175a73f30 Poland | |
| bee5ac1a-20ce-45da-8e66-dbde8c6e78d4 Greece | |
| 1f7ab357-5d5c-4811-bd17-ed65f847a913 Estonia | |
| 6318e9b6-8986-4a65-81ee-2a203c28fe89 Czech Republic | |
| 0a182ce7-658f-4001-b6e5-e97a63b4e4d3 Poland | |
| 05b99410-fb7b-470a-ae90-29771bc6cd22 Belgium | |
| 240f81aa-6950-4a5f-83f7-9be446290d0b France | |
| d05252ab-2825-4fd8-92d1-f1aa153a811b Sweden | |
| c1ec4c2e-6b04-4c80-87ab-08c638c3a7ab Sweden | |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SCC303003C0201 |
| Instructions and Manuals | 1SCC303008M0208 |
| Environmental Product Declaration - EPD | 1SCC303082D0201 |
| Environmental | |
| Degree of Protection | Front IP20 |
| Environmental Information | 1SCC303050D0201 |
| Pollution Degree | 3 |
| Ordering | |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Country or Territory of Origin | Finland |
| Dimensions | |
| Product Net Width | 194 mm |
| 7.64 in | |
| Product Net Height | 170 mm |
| 6.69 in | |
| Product Net Depth / Length | 160 mm |
| 6.3 in | |
| Product Net Weight | 2.68 kg |
| 5.91 lb | |
| Container Information | |
| Package Level 1 Units | box 1 box |
| Package Level 1 Width | 186 mm |
| 7.32 in | |
| Package Level 1 Depth / Length | 300 mm |
| 11.81 in | |
| Package Level 1 Height | 185 mm |
| 7.28 in | |
| Package Level 1 Gross Weight | 2.98 kg |
| 6.57 lb | |
| Package Level 1 EAN | 6417019252018 |
| Technical | |
| Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 160 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 160 A |
| Degree of Protection | Front IP20 |
| Distance Between Phases | Standard |
| Handle Color | Black |
| Handle Type | Handle and shaft included |
| Mounting Type | Base mounting |
| Number of Poles | 3P |
| Operating Mode | Front |
| Pollution Degree | 3 |
| Position of Line Terminals | Top In - Bottom Out, Bottom In - Top Out |
| Power Loss | at Rated Operating Conditions per Pole 2.4 W |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 160 A |
| (500 V) 160 A | |
| (690 V) 160 A | |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 160 A |
| (500 V) 160 A | |
| (690 V) 160 A | |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 160 A |
| (500 V) 160 A | |
| (690 V) 160 A | |
| Rated Operational Current AC-31B (Ie) | (380 ... 415 V) 160 A |
| Rated Operational Current AC-33B (Ie) | (380 ... 415 V) 160 A |
| Rated Operational Power AC-23A (Pe) | (380 ... 415 V) 90 kW |
| (500 V) 110 kW | |
| (690 V) 160 kW | |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 8 kiloampere rms |
| Switches Operating Mechanism | Mechanism at the End of the Switch |
| 03 (Left Side) | |
| Terminal Type | Screw Terminals |
| Terminal Width | 20 mm |
| Tightening Torque | acc. IEC 60947-1 15 ... 22 N·m |
| Transition Type | Open |
| Technical UL/CSA | |
| Tightening Torque | acc. IEC 60947-1 15 ... 22 N·m |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 1SCC303001D2704 |
| DNV Certificate | 1SCC303138D0201 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| ETIM 10 | EC000216 - Switch disconnector (AC) |
| UNSPSC | 39122233 |
| eClass | V11.1 : 27371403 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| E-Number (Finland) | 3641518 |