View larger
1SCA022744R3560 ABB Disconnector switch OT250E03WP
1SCA022744R3560
022744
ABB
1 Pcs.
Connectors > Switch disconnector
Manual Switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An 1SCA022744R3560 ABB Disconnector switch OT250E03WP is a robust industrial load break switch used to create a visible break in electrical circuits, ensuring technician safety during repairs. These switches are typically installed in electrical distribution boards to safely handle medium-to-high amperage power switching requirements.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- End Of Life Disassembling Instructions: 1SCC301117M0201
- Environmental Information: 1SCC301265D0201
- Environmental Product Declaration - EPD: 1SCC301282D0201
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- REACH Declaration: 1SCC011021D0201
- RoHS Declaration: 1SCC011020D0201
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 9d2fd67a-f690-4bf2-b98b-8d1174018ee9 Finland
- Simplified SCIP: ab95594a-afae-43d6-b9d4-9693f3d1ed0b Germany
- Toxic Substances Control Act - TSCA: 1SCC011025D0201
- Data Sheet, Technical Information: 1SCC301020C0201
- Instructions and Manuals: 1SCC301031M0220
- Mechanical Drawings: 1SCC301290F0001
- Environmental Product Declaration - EPD: 1SCC301282D0201
- Degree of Protection: Front IP00
- Environmental Information: 1SCC301265D0201
More info
▲| ABB EcoSolutions | |
|---|---|
| End Of Life Disassembling Instructions | 1SCC301117M0201 |
| Environmental Information | 1SCC301265D0201 |
| Environmental Product Declaration - EPD | 1SCC301282D0201 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SCC011021D0201 |
| RoHS Declaration | 1SCC011020D0201 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 9d2fd67a-f690-4bf2-b98b-8d1174018ee9 Finland |
| Simplified SCIP | ab95594a-afae-43d6-b9d4-9693f3d1ed0b Germany |
| 1c66e088-2940-40c2-a266-cca7762f8ee8 Belgium | |
| 7c377033-a217-4b8d-a9c2-75a24b0a2d8f Italy | |
| 4b495af2-e067-4217-9dcd-107678ff1413 Germany | |
| ec62897e-a723-4ece-b6c5-c942e2fc6503 Hungary | |
| 2098dd86-fae7-4fe7-a7ac-3f1e6729262a Netherlands | |
| f5fb0cb5-75fb-46c7-a1cb-04e6c3d7c60c Sweden | |
| 2189db65-0c68-42fc-8491-c652ffaa92d0 Poland | |
| bb37739a-45e0-4765-8fd4-afdd2fe2d8a8 Sweden | |
| ff2cb2e1-73ad-4af3-b605-9f2112a2cfa1 Germany | |
| 53c247a3-ea1d-4488-a91a-a46139162232 Portugal | |
| 30aa7913-265a-43a6-8ece-75919e3615d3 Poland | |
| f37d1b84-ee7a-4369-a190-809344fc7ffa Estonia | |
| 006669de-fd9a-4905-8d7f-e4fb6190d563 Greece | |
| 6f0e0560-4060-4df5-b979-0e3c3f72c62f Bulgaria | |
| dec43b05-783a-4935-be7c-922b30e339bd Norway | |
| aa4fd932-1cf1-46c6-a478-c507aa7ef8a0 France | |
| 16110378-d1c0-46d1-9c84-d9a3faee245e Poland | |
| 9c5e5a1f-057a-439a-a5d8-61cdd0852be8 Spain | |
| 74e6ea84-c8bc-4cd1-8b26-6bfcd6de58c3 Belgium | |
| 8a2b0926-999b-44a0-af9f-57eb00240450 Hungary | |
| 910c4e23-6a9f-485e-93ef-bed8730c69df Czech Republic | |
| fda1dead-6015-42eb-90d1-c3636681e9a6 Germany | |
| b44f5f6f-711a-4466-8655-fe9a1f84d190 Denmark | |
| 1b8e8ad8-8fd0-420c-b99e-cc9f50d0eea5 Croatia | |
| 1f63380c-2bf4-4f3b-98b8-711074efc6d7 France | |
| ea8683a2-cc66-424b-8750-26456e08e6b8 Germany | |
| Toxic Substances Control Act - TSCA | 1SCC011025D0201 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SCC301020C0201 |
| Instructions and Manuals | 1SCC301031M0220 |
| Mechanical Drawings | 1SCC301290F0001 |
| 1SCC301289F0001 | |
| OT200-250E03W.stp | |
| OT200-250E03W.igs | |
| Environmental Product Declaration - EPD | 1SCC301282D0201 |
| Environmental | |
| Degree of Protection | Front IP00 |
| Environmental Information | 1SCC301265D0201 |
| Pollution Degree | 3 |
| Ordering | |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Country or Territory of Origin | Finland |
| Dimensions | |
| Product Net Width | 169.5 mm |
| Product Net Height | 170 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 190 mm |
| 7.5 in | |
| Package Level 1 Depth / Length | 290 mm |
| 11.4 in | |
| Package Level 1 Height | 110 mm |
| 4.3 in | |
| Package Level 1 Gross Weight | 1.7 kg |
| 3.7 lb | |
| Package Level 1 EAN | 6417019241418 |
| Technical | |
| Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 250 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 250 A |
| Degree of Protection | Front IP00 |
| Distance Between Phases | Wide phase distance |
| Handle Color | Black |
| Handle Type | Handle and shaft included |
| Mechanical Durability | 20000 |
| Mounting Type | Base mounting |
| Number of Poles | 3P |
| Operating Mode | Front |
| Pollution Degree | 3 |
| Position of Line Terminals | Top In - Bottom Out |
| Bottom In - Top Out | |
| Power Loss | at Rated Operating Conditions per Pole 6.5 W |
| Rated Conditional Short-Circuit Current (Inc) | (315 A fuse, 500 V) 100 kA |
| (355 A fuse, 690 V) 80 kA | |
| (250 A fuse, 690 V) 100 kA | |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 1000 V |
| Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 250 A |
| (500 V) 250 A | |
| (690 V) 250 A | |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 250 A |
| (500 V) 250 A | |
| (690 V) 250 A | |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 250 A |
| (500 V) 250 A | |
| (690 V) 250 A | |
| Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 75 kW |
| (400 ... 415 V) 145 kW | |
| (500 V) 170 kW | |
| (690 V) 250 kW | |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Short-Circuit Making Capacity (Icm) | (690 V) 30 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 8 kA |
| Special Functions | Wide phase distance |
| Standards | IEC 60947-3 |
| Switches Operating Mechanism | Mechanism at the End of the Switch |
| 03 (Left Side) | |
| Terminal Type | Lug terminals |
| Terminal Width | 20 mm |
| Tightening Torque | acc. IEC 60947-1 15 … 22 N·m |
| Technical UL/CSA | |
| Tightening Torque | acc. IEC 60947-1 15 … 22 N·m |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SCC301337D0201 |
| ATEX Certificate | No certification needed |
| BV Certificate | 1SCC301103D0201 |
| Declaration of Conformity - CE | 1SCC301131D2705 |
| DNV GL Certificate | 1SCC301174D0204 |
| GL Certificate | 1SCC301139D0201 |
| LR Certificate | 1SCC301144D0201 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| ETIM 10 | EC000216 - Switch disconnector (AC) |
| UNSPSC | 39122221 |
| eClass | V11.1 : 27371403 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| E-Number (Finland) | 3661328 |
| E-Number (Norway) | 4337884 |
| E-Number (Sweden) | 3171190 |