View larger
1SCA022608R8190 ABB Int. Boxed disconnector OTP16H3M
1SCA022608R8190
022608
ABB
1 Pcs.
Connectors > Switch disconnector
Manual Switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB boxed disconnector, listed under part number 1SCA022608R8190, provides protected circuit isolation in harsh or exposed industrial locations. Housed disconnectors are commonly mounted near remote motors or external equipment to grant local, weather-resistant power interruption capabilities. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- REACH Declaration: 1SCC340076D0201
- RoHS Declaration: 1SCC340075D0201
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Toxic Substances Control Act - TSCA: 1SCC340095D0201
- Data Sheet, Technical Information: 1SCC340015C0201
- Instructions and Manuals: 1SCC340002M0012
- Degree of Protection: acc. to IEC 60529 IP65
- Pollution Degree: 3
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85363030
- Last Ordering Date: 2026-08-31 All Countries
- Replacement Product ID (NEW): OTP16GK3M
- Country or Territory of Origin: Finland
- Product Net Width: 85 mm
- Product Net Height: 120 mm
More info
▲| Material Compliance | |
|---|---|
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SCC340076D0201 |
| RoHS Declaration | 1SCC340075D0201 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 1SCC340095D0201 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SCC340015C0201 |
| Instructions and Manuals | 1SCC340002M0012 |
| Environmental | |
| Degree of Protection | acc. to IEC 60529 IP65 |
| Pollution Degree | 3 |
| Ordering | |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85363030 |
| Last Ordering Date | 2026-08-31 All Countries |
| Replacement Product ID (NEW) | OTP16GK3M |
| Country or Territory of Origin | Finland |
| Dimensions | |
| Product Net Width | 85 mm |
| Product Net Height | 120 mm |
| Product Net Depth / Length | 60 mm |
| Product Net Weight | 0.4 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 106 mm |
| Package Level 1 Depth / Length | 158 mm |
| Package Level 1 Height | 97 mm |
| Package Level 1 Gross Weight | 0.5 kg |
| Package Level 1 EAN | 6417019198156 |
| Technical | |
| Cable Cross-Section | 0.75 ... 10 mm² |
| Cable Entry Position | Top/Bottom |
| Cable Outlets Per Side | 2xM20 / 2xM20 |
| Color | RAL9001 |
| Connecting Capacity Main Circuit | Screw Clamp 0.75 ... 10 mm² |
| Screw Clamp / PE Terminal 2pc,0.75 ... 2.5 mm² | |
| Conventional Thermal Current (Ithe) | Fully Enclosed 40 A |
| Degree of Protection | acc. to IEC 60529 IP65 |
| Enclosure Material | Plastic |
| Handle Color | White |
| Handle Type | Selector handle |
| Impact Resistance Rating | Housing IK08 |
| Maximum Mounted Auxiliary Contacts | 1 NO, 1 NC |
| Mounted Auxiliary Contacts | 1 NO, 0 NC |
| Neutral Type | Fixed Neutral |
| Number of Auxiliary Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Poles | 3P |
| Pollution Degree | 3 |
| Position of Line Terminals | Top In - Bottom Out |
| Position of Neutral Terminals | Top In - Bottom Out |
| Position of PE Terminals | Top In - Bottom Out |
| Power Loss | at Rated Operating Conditions per Pole 1.6 W |
| Rated Impulse Withstand Voltage (Uimp) | 0.5 kV |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 750 V |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 32 A |
| (500 V) 32 A | |
| (690 V) 32 A | |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 16 A |
| (500 V) 16 A | |
| (690 V) 10 A | |
| Rated Operational Power AC-23A (Pe) | (380 ... 415 V) 7.5 kW |
| (500 V) 7.5 kW | |
| (690 V) 7.5 kW | |
| Rated Operational Voltage | Main Circuit 750 V |
| Rated Short-Circuit Making Capacity (Icm) | (690 V AC) 0.705 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 0.5 kA |
| Standards | IEC 60947-1, -3 |
| Tightening Torque | Main Circuit 0.8 N·m |
| Wire Stripping Length | 10 mm |
| Technical UL/CSA | |
| Wire Stripping Length | 10 mm |
| Tightening Torque | Main Circuit 0.8 N·m |
| Certificates and Declarations | |
| BV Certificate | 1SCC340018D0204 |
| Declaration of Conformity - CE | 1SCC340003D2704 |
| DNV GL Certificate | 1SCC340045D0203 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| ETIM 10 | EC000216 - Switch disconnector (AC) |
| UNSPSC | 39122205 |
| IDEA Granular Category Code (IGCC) | 5166 >> Safety switch |
| eClass | V11.1 : 27371403 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| E-Number (Sweden) | 3140142 |