View larger
1SCA022497R0220 ABB OT16M3 disconnect switch
1SCA022497R0220
022497
ABB
1 Pcs.
Connectors > Switch disconnector
Manual Switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb OT16M3 disconnect switch provides reliable manual circuit isolation for compact control panels and low-voltage electrical distribution applications. These modular disconnects allow technicians to securely de-energize specific machine segments for routine maintenance. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Environmental Information: 1SCC301262D0201
- Environmental Product Declaration - EPD: 1SCC301278D0201
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- REACH Declaration: 1SCC011021D0201
- RoHS Declaration: 1SCC011020D0201
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Toxic Substances Control Act - TSCA: 1SCC011025D0201
- Data Sheet, Technical Information: 1SCC301020C0201
- Instructions and Manuals: 1SCC301052M0006
- Environmental Product Declaration - EPD: 1SCC301278D0201
- Degree of Protection: Front IP20
- Environmental Information: 1SCC301262D0201
- Pollution Degree: 3
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85365080
- Country or Territory of Origin: Finland
More info
▲| ABB EcoSolutions | |
|---|---|
| Environmental Information | 1SCC301262D0201 |
| Environmental Product Declaration - EPD | 1SCC301278D0201 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SCC011021D0201 |
| RoHS Declaration | 1SCC011020D0201 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 1SCC011025D0201 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SCC301020C0201 |
| Instructions and Manuals | 1SCC301052M0006 |
| Environmental Product Declaration - EPD | 1SCC301278D0201 |
| Environmental | |
| Degree of Protection | Front IP20 |
| Environmental Information | 1SCC301262D0201 |
| Pollution Degree | 3 |
| Ordering | |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Country or Territory of Origin | Finland |
| Dimensions | |
| Product Net Width | 35 mm |
| Product Net Height | 68 mm |
| Product Net Depth / Length | 73 mm |
| Product Net Weight | 0.09 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 82 mm |
| Package Level 1 Depth / Length | 103 mm |
| Package Level 1 Height | 86 mm |
| Package Level 1 Gross Weight | 0.1 kg |
| Package Level 1 EAN | 6417019158389 |
| Technical | |
| Cable Cross-Section | Cu 0.75 ... 10 mm² |
| Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 25 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 25 A |
| Degree of Protection | Front IP20 |
| Distance Between Phases | Standard |
| Handle Type | Handle and shaft not included |
| Mechanical Durability | 20000 |
| Mounting Type | Base mounting |
| Number of Poles | 3P |
| Operating Mode | Front |
| Pollution Degree | 3 |
| Position of Line Terminals | Top In - Bottom Out |
| Bottom In - Top Out | |
| Power Loss | at Rated Operating Conditions per Pole 0.3 W |
| Rated Conditional Short-Circuit Current (Inc) | (40 A fuse, ≤415V) 50 kA |
| (25 A fuse, 690 V) 50 kA | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 750 V |
| Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 16 A |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 16 A |
| (500 V) 16 A | |
| (690 V) 16 A | |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 16 A |
| (500 V) 16 A | |
| (690 V) 10 A | |
| Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 3 kW |
| (400 ... 415 V) 7.5 kW | |
| (500 V) 7.5 kW | |
| (690 V) 7.5 kW | |
| Rated Operational Voltage | Main Circuit 750 V |
| Rated Short-Circuit Making Capacity (Icm) | (690 V) 0.71 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 0.5 kA |
| Special Functions | No |
| Standards | IEC 60947-3 |
| Switches Operating Mechanism | Mechanism on Top of the Switch |
| Terminal Type | Screw Terminals |
| Tightening Torque | acc. IEC 60947-1 0.8 N·m |
| Technical UL/CSA | |
| Tightening Torque | acc. IEC 60947-1 0.8 N·m |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SCC301335D0201 |
| ATEX Certificate | No certification needed |
| Declaration of Conformity - CE | 1SCC301166D2703 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| ETIM 10 | EC000216 - Switch disconnector (AC) |
| UNSPSC | 39122233 |
| eClass | V11.1 : 27371403 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| E-Number (Sweden) | 3171075 |