1SBL361201R8500 ABB AFC52-40-00-85 380-400V50Hz 400-415V60Hz
1SBL361201R8500
1SBL361201R8500
ABB
1 Pcs.
Automation > Power contactor, AC switching
Contactors and overload relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ABB 1SBL361201R8500 contactor operates as an electromechanical switching device engineered to handle robust electrical loads and automated industrial equipment. Devices of this category are frequently integrated into high-demand control panels for seamless power regulation. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 1SBC100219C0201
- Instructions and Manuals: 1SBC101047M6801
- Instructions and Manuals (Part 2): 1SAC200017M0002
- Product Net Width: 70 mm
- Product Net Depth / Length: 119.5 mm
- Product Net Height: 113.5 mm
- Product Net Weight: 1.18 kg
- Number of Main Contacts NO: 4
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 0
- Number of Poles: 4P
- Rated Operational Voltage: Main Circuit 690 V
- Conventional Free-air Thermal Current (I th ): acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC100219C0201 |
| Instructions and Manuals | 1SBC101047M6801 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| Dimensions | |
| Product Net Width | 70 mm |
| Product Net Depth / Length | 119.5 mm |
| Product Net Height | 113.5 mm |
| Product Net Weight | 1.18 kg |
| Technical | |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1 |
| Rated Operational Voltage | Main Circuit 690 V |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 100 A |
| (690 V) 60 °C 80 A | |
| (690 V) 70 °C 70 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 53 A |
| (440 V) 60 °C 53 A | |
| (500 V) 60 °C 45 A | |
| (690 V) 60 °C 35 A | |
| (380 / 400 V) 60 °C 53 A | |
| (220 / 230 / 240 V) 60 °C 53 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 30 kW |
| (440 V) 30 kW | |
| (500 V) 30 kW | |
| (690 V) 30 kW | |
| (380 / 400 V) 22 kW | |
| (220 / 230 / 240 V) 15 kW | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| (AC-2 / AC-4) 0 cycles per hour | |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz 380 ... 400 V |
| 60 Hz 400 ... 415 V | |
| Coil Consumption | Average Holding Value 50 / 60 Hz 20 V·A |
| Average Pull-in Value 50 Hz 150 V·A | |
| Average Pull-in Value 60 Hz 151 V·A | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 6.3 W |
| at Rated Operating Conditions AC-3 per Pole 1.7 W | |
| Operate Time | Between Coil De-energization and NO Contact Opening 4 ... 14 ms |
| Between Coil Energization and NO Contact Closing 7 ... 21 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 or 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 4 ... 35 mm² |
| Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | |
| Rigid 1/2x 6 ... 3 5 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
| Rigid 1/2x 1 ... 2.5 mm² | |
| Wire Stripping Length | Control Circuit 10 mm |
| Main Circuit 16 mm | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Recommended Screw Driver | Pozidriv PZ |
| Tightening Torque | Control Circuit 1.2 N·m |
| Main Circuit 4 N·m | |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 80 A |
| Tightening Torque UL/CSA | Control Circuit 11 in·lb |
| Main Circuit 35 in·lb | |
| Full Load Amps Motor Use | (120 V AC) Single Phase 3 A |
| (200 ... 208 V AC) Three Phase 15 A | |
| (220 ... 240 V AC) Three Phase 20 A | |
| (240 V AC) Single Phase 10 A | |
| (440 ... 480 V AC) Three Phase 40 A | |
| (550 ... 600 V AC) Three Phase 50 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor without Thermal O/L Relay -40 ... 70 °C |
| Close to Contactor for Storage -60 ... +80 °C | |
| Near Contactor for Operation in Free Air -40 ... 70 °C | |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| BV Certificate | BV_2634H36994A |
| CB Certificate | SE-114796 |
| CCC Certificate | 2020980304001074 |
| CCS Certificate | GZ23PTB00147 |
| CQC Certificate | CQC2012010304589737 |
| Declaration of Conformity - CE | 1SBD250025U1000 |
| Declaration of Conformity - UKCA | 1SBD250046U1000 |
| DNV Certificate | 9AKK108470A6934 |
| KC Certificate | 9AKK108471A9564 |
| RINA Certificate | 9AKK108470A5006 |
| UL Certificate | UL-CA-2337655-0 |
| UL-US-2343493-0 | |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 146.5 mm |
| Package Level 1 Depth / Length | 96.5 mm |
| Package Level 1 Height | 146.5 mm |
| Package Level 1 Gross Weight | 1.3 kg |
| Package Level 1 EAN | 3471523019324 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |