View larger
1SBL351074R8600 ABB AX50-30-00-86 400-415V50Hz 415-440V60Hz
1SBL351074R8600
351074
ABB
1 Pcs.
Automation > Power contactor, AC switching
Contactors and overload relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
AX50-30-00-86 400-415V50Hz 415-440V60Hz produced by ABB under part number 1SBL351074R8600 functions as a standard power contactor for establishing and breaking electrical circuits in industrial settings. Panel builders rely on these electromechanical units to control large motors, lighting systems, and distribution transformers via remote automation commands.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Instructions and Manuals: 9AKK107492A7059
- CAD Dimensional Drawing: 2CDC001079B0201
- Product Net Width: 70 mm
- Product Net Depth / Length: 110 mm
- Product Net Height: 108 mm
- Product Net Weight: 1.01 kg
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 0
- Rated Operational Voltage: Auxiliary Circuit 690 V
- Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (I th ): acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 A
- Rated Operational Current AC-1 (I e ): (220 / 240 V) 55 °C 85 A
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Instructions and Manuals | 9AKK107492A7059 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 70 mm |
| Product Net Depth / Length | 110 mm |
| Product Net Height | 108 mm |
| Product Net Weight | 1.01 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Main Circuit 690 V | |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 A |
| Rated Operational Current AC-1 (Ie) | (220 / 240 V) 55 °C 85 A |
| (690 V) 40 °C 100 A | |
| (690 V) 70 °C 70 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 50 A |
| (440 V) 55 °C 45 A | |
| (500 V) 55 °C 45 A | |
| (690 V) 55 °C 35 A | |
| (380 / 400 V) 55 °C 50 A | |
| (220 / 230 / 240 V) 55 °C 53 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 25 kW |
| (440 V) 25 kW | |
| (500 V) 30 kW | |
| (690 V) 30 kW | |
| (380 / 400 V) 22 kW | |
| (220 / 230 / 240 V) 15 kW | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A | |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| (AC-3) 600 cycles per hour | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz 400 ... 415 V |
| 60 Hz 415 ... 440 V | |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 14 ms |
| Between Coil De-energization and NO Contact Opening 4 ... 11 ms | |
| Between Coil Energization and NC Contact Opening 7 ... 22 ms | |
| Between Coil Energization and NO Contact Closing 8 ... 27 ms | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| IP10 | |
| Terminal Type | Screw Terminals |
| Technical UL/CSA | |
| General Use Rating UL/CSA | (600 V AC) 80 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3 hp |
| (200 ... 208 V AC) Three Phase 15 hp | |
| (220 ... 240 V AC) Three Phase 20 hp | |
| (240 V AC) Single Phase 10 hp | |
| (440 ... 480 V AC) Three Phase 40 hp | |
| (550 ... 600 V AC) Three Phase 50 hp | |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb |
| Control Circuit 9 in·lb | |
| Main Circuit 35 in·lb | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C |
| Close to Contactor without Thermal O/L Relay -40 ... 70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Near Contactor for Operation in Free Air -40 ... 70 °C | |
| Climatic Withstand | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Information | 2CMT2021-006277 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| CB Certificate | 9AKK107492A7074 |
| CCC Certificate | 9AKK107492A7091 |
| CCS Certificate | GZ23PTB00147 |
| CQC Certificate | CQC2013010304646607 |
| Declaration of Conformity - CCC | 2020980304001064 |
| Declaration of Conformity - CE | 1SBD250011U1000 |
| UL Certificate | UL_20140702-E312527-10-7 |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 102 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Height | 152 mm |
| Package Level 1 Gross Weight | 1.12 kg |
| Package Level 1 EAN | 3471522403865 |
| Package Level 2 Units | 10 piece |
| Package Level 2 Width | 240 mm |
| Package Level 2 Depth / Length | 295 mm |
| Package Level 2 Height | 145 mm |
| Package Level 2 Gross Weight | 11.2 kg |
| Classifications | |
| Object Classification Code | Q |
| ETIM 6 | EC000066 - Power contactor, AC switching |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |