Product Overview

A thermal overload relay functions as an electromechanical safety device that protects three-phase electric motors from overheating due to mechanical overloads or phase loss. This ABB TA75DU-63M Overload Relay mounts directly in motor starter configurations to disconnect power reliably.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • Instructions and Manuals: 2CDC106049M6802
  • Time-Current Characteristic Curve: 1SAZ300501F0005
  • CAD Dimensional Drawing: 2CDC001079B0201
  • Product Net Width: 54 mm
  • Product Net Height: 90 mm
  • Product Net Depth / Length: 111 mm
  • Product Net Weight: 0.335 kg
  • Rated Operational Voltage: Main Circuit 690 V AC
  • Rated Operational Current (I e ): 63 A
  • Number of Poles: 3P
  • Number of Auxiliary Contacts NC: 1
  • Number of Auxiliary Contacts NO: 1
  • Number of Protected Poles: 3
  • Conventional Free-air Thermal Current (I th ): Auxiliary Circuit NC 5 A

More info

▲
Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Instructions and Manuals2CDC106049M6802
Time-Current Characteristic Curve1SAZ300501F0005
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width54 mm
Product Net Height90 mm
Product Net Depth / Length111 mm
Product Net Weight0.335 kg
Technical
Rated Operational VoltageMain Circuit 690 V AC
Main Circuit 440 V DC
Rated Operational Current (Ie)63 A
Number of Poles3P
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NC 5 A
Auxiliary Circuit NO 5 A
Rated Operational Current AC-15 (Ie)(120 V) NC 3 A
(120 V) NO 1.5 A
(240 V) NC 3 A
(240 V) NO 1.2 A
(400 V) NC 0.75 A
(400 V) NO 0.37 A
(440 V) NC 0.75 A
(440 V) NO 0.37 A
(500 V) NC 0.3 A
(500 V) NO 0.25 A
Degree of ProtectionHousing IP20
Main Circuit Terminals IP20
Connecting Capacity Auxiliary CircuitFlexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm
Main Circuit 14 mm
Recommended Screw DriverAuxiliary Circuit Pozidriv 1
Main Circuit Pozidriv 2
Power Lossat Rated Operating Conditions per Pole 1.9 ... 3.8 W
Suitable ForAX50
AX65
AX80
StandardsCSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NC:) B600
(NO:) C600
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 8-1 AWG
Stranded 1/2x 8-1 AWG
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-14 AWG
Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 12 in·lb
Main Circuit 40 in·lb
Environmental
Ambient Air TemperatureOperation -25 ... +55 °C
Operation Compensated -25 ... +55 °C
Storage -40 ... +70 °C
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
CB Certificate1SAA941019-2001
CCC Certificate2024010304659817
CCS Certificate1SAA941000-0901
CQC CertificateCQC2016010309922937
Declaration of Conformity - CCC2020980304001322
Declaration of Conformity - CE1SAD101100-3501
EAC Certificate1SAA941002-2701
RMRS Certificate1SAA941000-0704
UL CertificateE48139-19970506
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width92 mm
Package Level 1 Height109 mm
Package Level 1 Depth / Length61 mm
Package Level 1 Gross Weight0.36 kg
Package Level 1 EAN4013614482663
Package Level 2 Units25 piece
Package Level 2 Width230 mm
Package Level 2 Height310 mm
Package Level 2 Depth / Length380 mm
Package Level 2 Gross Weight8.786 kg
External Classifications and Standards
ETIM 9EC000106 - Thermal overload relay
ETIM 10EC000106 - Thermal overload relay
eClassV11.0 : 27371501
UNSPSC39121520
IDEA Granular Category Code (IGCC)5364 >> Overload relay
E-Number (Finland)3707437

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.