View larger
1SAT143000R1011 ABB HF9-DOLE-24VDC
1SAT143000R1011
143000
ABB
1 Pcs.
Automation > Motor starter/Motor starter combination
Electronic relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Equipped with overload protection and an emergency stop function, the Abb 1SAT143000R1011 ABB HF9-DOLE-24VDC operates as an electronic direct-on-line motor starter. Electronic starters offer precise current monitoring and reliable solid-state switching for industrial motor control applications. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85371098
- Product Main Type: HF
- Product Name: Electronic Starter
- Data Sheet, Technical Information: 2CDC130009M0401
- Instructions and Manuals: 2CDC130009M0401
- Dimension Diagram: 1SAT100401F0001
- Product Net Width: 22.5 mm
- Product Net Height: 99 mm
- Product Net Depth / Length: 114.5 mm
- Product Net Weight: 0.218 kg
- Standards: IEC/EN 60947-1
- Function: Direct-on-line-starter with overload protection and emergency stop function
- Utilization: Motor Protection
- Rated Operational Voltage: Main Circuit 500 V AC
- Operational Voltage: Maximum 550 V AC
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85371098 |
| Product Main Type | HF |
| Product Name | Electronic Starter |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC130009M0401 |
| Instructions and Manuals | 2CDC130009M0401 |
| Dimension Diagram | 1SAT100401F0001 |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 99 mm |
| Product Net Depth / Length | 114.5 mm |
| Product Net Weight | 0.218 kg |
| Technical | |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-4-2 | |
| IEC/EN 61508 | |
| IS0 13849 | |
| UL 60947-1 | |
| UL 60947-4-2 | |
| Function | Direct-on-line-starter with overload protection and emergency stop function |
| Utilization | Motor Protection |
| Rated Operational Voltage | Main Circuit 500 V AC |
| Operational Voltage | Maximum 550 V AC |
| Minimum 42 V AC | |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Main Circuit 60 Hz | |
| Rated Control Supply Voltage (Us) | 24 V DC |
| Rated Input Voltage (UIN) | Switching Threshold at Signal <0> -3 ... 9.6 V |
| Switching Threshold at Signal <1> 19.2 ... 30 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
| Rated Insulation Voltage (Ui) | 500 V |
| Rated Operational Current AC-51 (Ie) | 9 A |
| Rated Operational Current AC-53a (Ie) | 6.5 A |
| Rated Control Supply Current (Is) | 0.04 A |
| Rated Uninterrupted Current (Iu) | 9 A |
| Input Current | 0.003 A |
| Switching Frequency | ≤ 2 Hz |
| 120 starts/min | |
| 7200 starts/h | |
| Rated Operational Power AC-53a (Pe) | 3 kW |
| Overvoltage Category | III |
| Overload Protection | Electronic overload protection |
| Setting Range | 1.5 ... 9.0 A |
| Trip Class | class 10A |
| Number of Poles | 3P |
| Power Loss | Maximum 14.6 W |
| Minimum 1.1 W | |
| Number of Protected Poles | 3 |
| Mechanical Durability | Nr. Operations 10000 cycle |
| Electrical Durability | 30000000 cycle |
| Delay Time (τ) | Off, Maximum, Switched Off via Control Input Voltage 80 ms |
| Off, Maximum, Switched Off via Supply Voltage 500 ms | |
| Off, Typical, Switched Off via Control Input Voltage 30 ms | |
| Off, Typical, Switched Off via Supply Voltage 25 ms | |
| Off, Maximum, Switched Off with Pushbutton 3 second [unit of time] | |
| Off, Minimum, Switched Off with Pushbutton 0.5 second [unit of time] | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting Position | 1 |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Rigid 1x 0.5 ... 4 mm² | |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1x 2 ... 2.5 mm² |
| Flexible 1x 2 ... 2.5 mm² | |
| Rigid 1x 2 ... 2.5 mm² | |
| Recommended Screw Driver | Control Circuit M3 |
| Main Circuit M3 | |
| Terminal Type | Screw Terminals |
| Tightening Torque | Control Circuit 0.5 ... 0.6 N·m |
| Main Circuit 0.5 ... 0.6 N·m | |
| Wire Stripping Length | Control Circuit 8 mm |
| Main Circuit 8 mm | |
| Response Time | Phase Asymmetry 33% 120 second [unit of time] |
| Phase Asymmetry 67% 1.8 second [unit of time] | |
| Phase Failure 1.8 second [unit of time] | |
| Pollution Degree | 2 |
| Phase Loss Sensitive | Yes |
| Degree of Protection | Housing IP20 |
| Main Circuit Terminals IP20 | |
| Short-Circuit Current Rating (SCCR) | (500 V AC, 30 A Class J or CC) 100 kA |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 500 V AC |
| Horsepower Rating UL/CSA | Nominal Switching Performance Full Load (power factor = 0.4) 3 Hp |
| Nominal Switching Performance Full Load (power factor = 0.8) 6.1 Hp | |
| Full Load Amps Motor Use | 6.5 A |
| Connecting Capacity Main Circuit UL/CSA | Flexible with Ferrule 1x 24 ... 14 AWG |
| Flexible 1x 24 ... 14 AWG | |
| Solid 1x 24 ... 14 AWG | |
| Connecting Capacity Control Circuit UL/CSA | Flexible with Ferrule 1x 24 ... 14 AWG |
| Flexible 16-8 AWG | |
| Solid 1x 24 ... 14 AWG | |
| Tightening Torque UL/CSA | Control Circuit 5 ... 7 in·lb |
| Main Circuit 5 ... 7 in·lb | |
| Safety Information | |
| Safety Integrity Level (SIL) | 3 |
| Safety Category | 3 |
| Performance Level (PL) | Up to e |
| Mean Time to Dangerous Failure (MTTFd) | Motor Protection 447 year |
| Safe Shutdown 518 year | |
| Mean Time to Failure (MTTF) | 43 year |
| Diagnostic Coverage | 98.91 % |
| Diagnostic Coverage Safe (DCS) | 38.91 % |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +70 °C |
| Operation Compensated -40 ... + 80 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SAA983001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006538 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| ATEX Certificate | 1SAA918002-3901 |
| CCC Certificate | 1SAA918005-3802 |
| cUL Certificate | cUL E191658 |
| Declaration of Conformity - CCC | 2020970304003456 |
| Declaration of Conformity - CE | 1SAD938504-0194 |
| Declaration of Conformity - UKCA | 1SAD938501-1194 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 150 mm |
| Package Level 1 Depth / Length | 115 mm |
| Package Level 1 Height | 34 mm |
| Package Level 1 Gross Weight | 0.318 kg |
| Package Level 1 EAN | 4013614515620 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 9 | EC001037 - Motor starter/motor starter combination |
| ETIM 10 | EC001037 - Motor starter/motor starter combination |
| eClass | V11.0 : 27370905 |
| UNSPSC | 39121521 |
| IDEA Granular Category Code (IGCC) | 4727 >> Motor starter controls |
| E-Number (Finland) | 3707545 |
| E-Number (Norway) | 4102021 |
| E-Number (Sweden) | 3210493 |