View larger
1SAM461000R1019 ABB MO165-80
1SAM461000R1019
461000
ABB
1 Pcs.
Automation > Motor protection circuit-breaker
Electronic motor protection relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
1SAM461000R1019 ABB MO165-80 from Abb is a manual motor starter engineered to provide magnetic short-circuit protection for high-current industrial electric motors. Devices of this category are installed within control cabinets to ensure rapid isolation during fault conditions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Data Sheet, Technical Information: 2CDC131084D0201
- Instructions and Manuals: 2CDC131082M6801
- Instructions and Manuals (Part 2): 2CDC131060M0202
- Time-Current Characteristic Curve: 1SAM400515F0008
- I²t Characteristic: 1SAM400506F0001
- Cut-off Current Characteristic: 1SAM400507F0001
- CAD Dimensional Drawing: 2CDC001079B0201
- Dimension Diagram: 1SAM400402F0001
- Product Net Width: 55 mm
- Product Net Height: 142.65 mm
- Product Net Depth / Length: 122 mm
- Product Net Weight: 1 kg
- Rated Service Short-Circuit Breaking Capacity (I cs ): (230 V AC) 30 kA
- Rated Ultimate Short-Circuit Breaking Capacity (I cu ): (230 V AC) 30 kA
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC131084D0201 |
| Instructions and Manuals | 2CDC131082M6801 |
| Instructions and Manuals (Part 2) | 2CDC131060M0202 |
| Time-Current Characteristic Curve | 1SAM400515F0008 |
| I²t Characteristic | 1SAM400506F0001 |
| Cut-off Current Characteristic | 1SAM400507F0001 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimension Diagram | 1SAM400402F0001 |
| Dimensions | |
| Product Net Width | 55 mm |
| Product Net Height | 142.65 mm |
| Product Net Depth / Length | 122 mm |
| Product Net Weight | 1 kg |
| Technical | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 30 kA |
| (250 V DC) 3 Poles in Series 100 kA | |
| (400 V AC) 30 kA | |
| (440 V AC) 18 kA | |
| (500 V AC) 10 kA | |
| (690 V AC) 6 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 30 kA |
| (250 V DC) 100 kA | |
| (400 V AC) 30 kA | |
| (440 V AC) 18 kA | |
| (500 V AC) 10 kA | |
| (690 V AC) 8 kA | |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 1120 A |
| Setting Range | None |
| Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 45 kW |
| Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 45 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Main Circuit 250 V DC | |
| Rated Operational Current (Ie) | 80 A |
| Rated Operational Current AC-3 (Ie) | 80 A |
| Rated Operational Current AC-3e (Ie) | 80 A |
| Rated Operational Current DC-5 (Ie) | 80 A |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Main Circuit 60 Hz | |
| Operating Frequency (fsw) | 0 ... 415 Hz |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Power Loss | at Rated Operating Conditions per Pole 6.27 W |
| Number of Poles | 3P |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 80 A |
| Degree of Protection | Housing IP20 |
| Main Circuit Terminals IP10 | |
| Pollution Degree | 3 |
| Electrical Durability | 20000 cycle |
| Mechanical Durability | Nr. Operations 50000 cycle |
| Terminal Type | Screw Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1 ... 35 mm² |
| Flexible with Insulated Ferrule 1/2x 1 ... 35 mm² | |
| Flexible 1/2x 1 ... 35 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Solid 1/2x 1 ... 4 mm² | |
| Stranded 1/2x 1 ... 50 mm² | |
| Tightening Torque | Main Circuit 4 N·m |
| Wire Stripping Length | Main Circuit 16 mm |
| Recommended Screw Driver | Pozidriv 2 |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm |
| Electrical Conductive Board, Horizontal - Up to 400 V 0 mm | |
| Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm | |
| Electrical Conductive Board, Vertical 75 mm | |
| Other Device Same Type, Horizontal 0 mm | |
| Other Device Same Type, Vertical 150 mm | |
| Actuator Type | Rotary Handle |
| Contact Position Indication | ON / OFF / TRIP |
| Standards | CSA 22.2 No. 14 |
| IEC/EN 60947-1 | |
| IEC/EN 60947-2 | |
| IEC/EN 60947-4-1 | |
| UL 60947-4-1 | |
| Remarks | For overload protection of the motors, an appropriate thermal or electronic overload relays must be used |
| Technical UL/CSA | |
| Short-Circuit Current Rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 50 kA |
| Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 10 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 50 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 10 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 50 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 10 kA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 25 Hp |
| (208 V AC) Three Phase 25 Hp | |
| (220 ... 240 V AC) Three Phase 30 Hp | |
| (440 ... 480 V AC) Three Phase 60 Hp | |
| (550 ... 600 V AC) Three Phase 75 Hp | |
| Full Load Amps Motor Use | (110 ... 120 V AC) Three Phase 56 A |
| (200 V AC) Three Phase 78.2 A | |
| (208 V AC) Three Phase 74.8 A | |
| (220 ... 240 V AC) Three Phase 80 A | |
| (440 ... 480 V AC) Three Phase 77 A | |
| (550 ... 600 V AC) Three Phase 77 A | |
| Locked Rotor Amps | (200 V AC) Three Phase 420 A |
| (208 V AC) Three Phase 404 A | |
| (220 ... 240 V AC) Three Phase 435 A | |
| (440 ... 480 V AC) Three Phase 435 A | |
| (550 ... 600 V AC) Three Phase 434 A | |
| General Use Rating UL/CSA | (600 V AC) 80 A |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-0 AWG |
| Stranded 1/2x 16-0 AWG | |
| Tightening Torque UL/CSA | Main Circuit 35 in·lb |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Operation Compensated -25 ... +60 °C | |
| Storage -50 ... +80 °C | |
| Ambient Air Temperature Compensation | No |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | Mounted on Mounting Plate: 5g 3 ... 150 Hz |
| Mounted on DIN-Rail: 4g 3 ... 150 Hz | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SAA963005-4502 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006539 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SAC200284H0001 |
| Environmental Product Declaration - EPD | 1SAC200253H0001 |
| Certificates and Declarations | |
| CB Certificate | 1SAA918002-2002 |
| CCC Certificate | 2024010307654703 |
| CQC Certificate | CQC2015010307760141 |
| Cut-off Current Characteristic | 1SAM400507F0001 |
| Declaration of Conformity - CCC | 2020980307003042 |
| Declaration of Conformity - CE | 1SAD101100-3409 |
| Declaration of Conformity - UKCA | 1SAD201100-3409 |
| EAC Certificate | 1SAA963000-2701 |
| IECEx Certificate | 1SAA918000-4001 |
| KC Certificate | 1SAA963001-1501 |
| UL Certificate | E137861-20150206 |
| E345003-20150206 | |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 64 mm |
| Package Level 1 Depth / Length | 177 mm |
| Package Level 1 Height | 140 mm |
| Package Level 1 Gross Weight | 1.1 kg |
| Package Level 1 EAN | 4013614536656 |
| Package Level 2 Units | carton 12 piece |
| Package Level 2 Width | 330 mm |
| Package Level 2 Depth / Length | 400 mm |
| Package Level 2 Height | 320 mm |
| Package Level 2 Gross Weight | 13 kg |
| Package Level 2 EAN | 4013614537844 |
| External Classifications and Standards | |
| Object Classification Code | F |
| ETIM 9 | EC000074 - Motor protection circuit-breaker |
| ETIM 10 | EC000074 - Motor protection circuit-breaker |
| eClass | V11.0 : 27370401 |
| UNSPSC | 39121521 |
| IDEA Granular Category Code (IGCC) | 4731 >> Manual Starters |
| E-Number (Finland) | 3708086 |
| E-Number (Norway) | 4364148 |