1SAM350010R1002 ABB MS132-0.25K Push-In Motor Guard
1SAM350010R1002
350010
ABB
1 Pcs.
Automation > Motor protection circuit-breaker
Electronic motor protection relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SAM350010R1002 MS132-0.25K Push-In Motor Guard is an advanced motor protection device built to shield electrical machinery from damaging fault currents and operational overloads. Motor guards monitor supply parameters in industrial automation setups, safely disconnecting circuits when abnormal electrical draws are detected. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362010
- Data Sheet, Technical Information: 1SBC100212C0203
- Instructions and Manuals: 2CDC131120M6801
- Instructions and Manuals (Part 2): 2CDC131060M0202
- Ex Operating Instructions: 2CDC131063M6801
- Time-Current Characteristic Curve: 1SAM300505F0102
- I²t Characteristic: 1SAM300507F0001
- Cut-off Current Characteristic: 1SAM300508F0001
- CAD Dimensional Drawing: 2CDC001079B0201
- Installation Video: 9AKK108466A6074
- Marketing Video: 9AKK107991A4712
- Product Net Width: 45 mm
- Product Net Height: 112 mm
- Product Net Depth / Length: 87 mm
- Product Net Weight: 0.256 kg
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362010 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC100212C0203 |
| Instructions and Manuals | 2CDC131120M6801 |
| Instructions and Manuals (Part 2) | 2CDC131060M0202 |
| Ex Operating Instructions | 2CDC131063M6801 |
| Time-Current Characteristic Curve | 1SAM300505F0102 |
| I²t Characteristic | 1SAM300507F0001 |
| 1SAM300507F0003 | |
| Cut-off Current Characteristic | 1SAM300508F0001 |
| 1SAM300508F0003 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Installation Video | 9AKK108466A6074 |
| 9AKK108466A6068 | |
| Marketing Video | 9AKK107991A4712 |
| 2CDC131153V0201 | |
| Dimensions | |
| Product Net Width | 45 mm |
| Product Net Height | 112 mm |
| Product Net Depth / Length | 87 mm |
| Product Net Weight | 0.256 kg |
| Technical | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 100 kA |
| (250 V DC) 3 Poles in Series 10 kA | |
| (400 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 100 kA |
| (400 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 3.1 A |
| Setting Range | 0.16 ... 0.25 A |
| Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 0.06 kW |
| Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 0.06 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Main Circuit 250 V DC | |
| Rated Operational Current (Ie) | 0.25 A |
| Rated Operational Current AC-3 (Ie) | 0.25 A |
| Rated Operational Current AC-3e (Ie) | 0.25 A |
| Rated Operational Current DC-5 (Ie) | 0.25 A |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Main Circuit 60 Hz | |
| Operating Frequency (fsw) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
| Rated Insulation Voltage (Ui) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.7 ... 1.6 W |
| Number of Poles | 3P |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 0.25 A |
| Degree of Protection | Housing IP20 |
| Main Circuit Terminals IP20 | |
| Pollution Degree | 3 |
| Electrical Durability | 50000 cycle |
| Mechanical Durability | Nr. Operations 100000 cycle |
| Terminal Type | Push-in Spring Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.5 ... 4 mm² |
| Flexible with Insulated Ferrule 1x 0.5 ... 4 mm² | |
| Flexible with Insulated Ferrule 2x 0.5 ... 2.5 mm² | |
| Flexible 1/2x 0.75 ... 4 mm² | |
| Solid 1/2x 1 ... 2.5 mm² | |
| Stranded 1/2x 1 ... 6 mm² | |
| Wire Stripping Length | Main Circuit 12 mm |
| Recommended Screw Driver | Pozidriv 2 |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm |
| Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm | |
| Electrical Conductive Board, Vertical 75 mm | |
| Other Device Same Type, Horizontal 0 mm | |
| Other Device Same Type, Vertical 150 mm | |
| Actuator Type | Rotary Handle |
| Contact Position Indication | ON / OFF / TRIP |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-2 | |
| IEC/EN 60947-4-1 | |
| UL 60947-1 | |
| UL 60947-4-1 | |
| IEC 60335-2-40 A2L | |
| Remarks | UL508 Self-Protected Combination Motor Controller (Type E) in combination with terminal spacer TS1-M3-K |
| Technical UL/CSA | |
| Short-Circuit Current Rating (SCCR) | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA |
| Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Full Load Amps Motor Use | (200 V AC) Three Phase 0.25 A |
| (208 V AC) Three Phase 0.25 A | |
| (220 ... 240 V AC) Three Phase 0.25 A | |
| (440 ... 480 V AC) Three Phase 0.25 A | |
| (550 ... 600 V AC) Three Phase 0.25 A | |
| Locked Rotor Amps | (200 V AC) Three Phase 1.5 A |
| (208 V AC) Three Phase 1.5 A | |
| (220 ... 240 V AC) Three Phase 1.5 A | |
| (440 ... 480 V AC) Three Phase 1.5 A | |
| (550 ... 600 V AC) Three Phase 1.5 A | |
| General Use Rating UL/CSA | (600 V AC) 0.25 A |
| Connecting Capacity Main Circuit UL/CSA | Stranded 1/2x 18-10 AWG |
| Stranded 1x 8 AWG | |
| Environmental | |
| Ambient Air Temperature | Around the Enclosure 0 ... +40 °C |
| Operation -25 ... +70 °C | |
| Operation Compensated -25 ... +60 °C | |
| Storage -50 ... +80 °C | |
| Ambient Air Temperature Compensation | Yes |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | 5g 3 ... 150 Hz |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SAA963005-4502 |
| RoHS Declaration | 1SAA963006-4502 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006539 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SAC200333H0001 |
| Environmental Product Declaration - EPD | 1SAC200360H0001 |
| 1SAC200385H0001 | |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SAA963000-4601 |
| ABS Certificate | 1SAA963001-0101 |
| ATEX Certificate | 1SAA963000-3902 |
| CB Certificate | 1SAA963002-2002 |
| CCC Certificate | 2024010307658958 |
| CQC Certificate | CQC2017010307034621 |
| Cut-off Current Characteristic | 1SAM300508F0001 |
| 1SAM300508F0003 | |
| Declaration of Conformity - CCC | 2020980307004600 |
| Declaration of Conformity - CE | 1SAD101100-3402 |
| Declaration of Conformity - UKCA | 1SAD201100-3402 |
| DNV GL Certificate | 1SAA963001-0304 |
| EAC Certificate | 1SAA963004-2701 |
| IECEx Certificate | 1SAA963000-4001 |
| KC Certificate | 1SAA963002-1502 |
| RINA Certificate | 1SAA963002-0802 |
| UL Certificate | E137861-20090225 |
| E345003-20090225 | |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 50 mm |
| Package Level 1 Depth / Length | 117 mm |
| Package Level 1 Height | 82 mm |
| Package Level 1 Gross Weight | 0.282 kg |
| Package Level 1 EAN | 4013614400322 |
| Package Level 2 Units | carton 28 piece |
| Package Level 2 Width | 280 mm |
| Package Level 2 Depth / Length | 395 mm |
| Package Level 2 Height | 210 mm |
| Package Level 2 Gross Weight | 14.026 kg |
| Package Level 2 EAN | 4013614522642 |
| External Classifications and Standards | |
| Object Classification Code | F |
| ETIM 9 | EC000074 - Motor protection circuit-breaker |
| ETIM 10 | EC000074 - Motor protection circuit-breaker |
| eClass | V11.0 : 27370401 |
| UNSPSC | 39121521 |
| IDEA Granular Category Code (IGCC) | 4731 >> Manual Starters |
| E-Number (Finland) | 3707832 |
| E-Number (Sweden) | 3110451 |