View larger
1SAL100175R9901 ABB MC1A301ARJ Mini Contactor
1SAL100175R9901
100175
ABB
1 Pcs.
Automation > Power contactor, AC switching
Contactors and overload relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Abb 1SAL100175R9901 mini contactor is a space-saving switching solution designed for OEM machinery and compact control panel integration. These miniature units control auxiliary circuits and smaller motor loads efficiently where panel space is restricted. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85365080
- EPLAN Data: 9AAC426184_EPLAN
- Data Sheet, Technical Information: 1SBC100214C0202
- Instructions and Manuals: 2CDC103061M6801
- CAD Dimensional Drawing: 2CDC001079B0201
- Product Net Width: 45 mm
- Product Net Depth / Length: 56 mm
- Product Net Height: 48 mm
- Product Net Weight: 0.17 kg
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 1
- Number of Poles: 3P
- Standards: IEC/EN 60947-1
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Popular Downloads | |
| EPLAN Data | 9AAC426184_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 2CDC103061M6801 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 56 mm |
| Product Net Height | 48 mm |
| Product Net Weight | 0.17 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-4-1 | |
| IEC/EN 60947-5-1 | |
| UL 60947-1 | |
| UL 60947-4-1 | |
| UL 60947-5-1 | |
| Rated Operational Voltage | Auxiliary Circuit 690 V AC |
| Auxiliary Circuit 440 V DC | |
| Main Circuit 690 V AC | |
| Main Circuit 440 V DC | |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz |
| Auxiliary Circuit 60 Hz | |
| Auxiliary Circuit DC | |
| Control Circuit 50 Hz | |
| Control Circuit 60 Hz | |
| Main Circuit 50 Hz | |
| Main Circuit 60 Hz | |
| Main Circuit DC | |
| Conventional Free-air Thermal Current (Ith) | Auxiliary Circuit 10 A |
| Main Circuit 20 A | |
| Rated Operational Current AC-1 (Ie) | (690 V) 55 °C 20 A |
| (690 V) 70 °C 16 A | |
| (230 V) 55 °C 20 A | |
| (230 V) 70 °C 16 A | |
| (400 V) 55 °C 20 A | |
| (400 V) 70 °C 16 A | |
| (500 V) 55 °C 20 A | |
| (500 V) 70 °C 16 A | |
| Rated Operational Current AC-3 (Ie) | (230 V) 55°C 9 A |
| (400 V) 55 °C 9 A | |
| (500 V) 55 °C 8 A | |
| (690 V) NO 55°C 5 A | |
| Rated Operational Current AC-15 (Ie) | (240 V) 6 A |
| (400 V) 4 A | |
| (500 V) 2.5 A | |
| (690 V) 1.5 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 5 A |
| (48 V) 2.5 A | |
| (125 V) 0.55 A | |
| (250 V) 0.3 A | |
| (440 V) 0.15 A | |
| Rated Operational Power AC-3 (Pe) | (230 V) Three Phase 2.2 kW |
| (400 V) Three Phase 4 kW | |
| (500 V) Three Phase 4 kW | |
| (690 V) Three Phase, NO 4 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A |
| Rated Insulation Voltage (Ui) | 750 V |
| Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV |
| Main Circuit 6 kV | |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-15) 360 cycles per hour | |
| (AC-3) 1200 cycles per hour | |
| (DC-1) 600 cycles per hour | |
| (DC-13) 360 cycles per hour | |
| (DC-3) 600 cycles per hour | |
| Mechanical Durability | Nr. Operations 10000000 cycle |
| Minimum Switching Capacity | Auxiliary Circuit 17 V |
| Auxiliary Circuit 5 mA | |
| Coil Operating Limits | (acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 110 ... 115 V AC |
| 60 Hz 110 ... 120 V AC | |
| Coil Consumption | Average Holding Value 50 Hz 5.3 V·A |
| Average Pull-in Value 50 Hz 5.3 V·A | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 0.7 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Connecting Capacity Main Circuit | Flexible 1/2x 0.75 ... 2.5 mm² |
| Rigid 1/2x 0.75 ... 2.5 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible 1/2x 0.75 ... 2.5 mm² |
| Rigid 1/2x 0.75 ... 2.5 mm² | |
| Connecting Capacity Control Circuit | Flexible 1/2x 0.75 ... 2.5 mm² |
| Rigid 1/2x 0.75 ... 2.5 mm² | |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Control Circuit 9 mm | |
| Main Circuit 9 mm | |
| Degree of Protection | Auxiliary Circuit Terminals IP20 |
| Control Circuit Terminals IP20 | |
| Main Circuit Terminals IP20 | |
| Recommended Screw Driver | Pozidriv 2 |
| Tightening Torque | Auxiliary Circuit 0.8 ... 1.0 N·m |
| Control Circuit 0.8 N·m | |
| Main Circuit 0.8 ... 1.0 N·m | |
| Terminal Type | Ring-Tongue Terminals |
| Mini Contactor Type | Mini Contactor |
| Product Name | Mini Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| General Use Rating UL/CSA | (600 V AC) 20 A |
| Horsepower Rating UL/CSA | (115 V AC) Single Phase 0.5 Hp |
| (200 V AC) Three Phase 3 Hp | |
| (220 ... 240 V AC) Three Phase 3 Hp | |
| (230 V AC) Single Phase 1.5 Hp | |
| (440 ... 480 V AC) Three Phase 5 Hp | |
| (550 ... 600 V AC) Three Phase 5 Hp | |
| Connecting Capacity Main Circuit UL/CSA | Stranded 1/2x 18-12 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Stranded 1/2x 18-12 AWG |
| Contact Rating UL/CSA | A600 |
| Q600 | |
| Tightening Torque UL/CSA | Auxiliary Circuit 7 in·lb |
| Control Circuit 7 in·lb | |
| Main Circuit 7 in·lb | |
| Full Load Amps Motor Use | (115 V AC) Single Phase 9.8 A |
| (200 V AC) Three Phase 11 A | |
| (220 ... 240 V AC) Three Phase 9.6 A | |
| (230 V AC) Single Phase 10 A | |
| (440 ... 480 V AC) Three Phase 7.6 A | |
| (550 ... 600 V AC) Three Phase 6.1 A | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... +70 °C |
| Storage -55 ... +80 °C | |
| Maximum Operating Altitude Permissible | 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | 5g 3 ... 150 Hz |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SAA971000-4601 |
| BV Certificate | 1SAA971000-0201 |
| CB Certificate | 1SAA971000-2001 |
| CQC Certificate | CQC2019010304197131 |
| Declaration of Conformity - CCC | 2020980304001602 |
| Declaration of Conformity - CE | 1SAD101100-3201 |
| Declaration of Conformity - UKCA | 1SAD201100-3201 |
| RINA Certificate | 1SAA971000-0801 |
| UL Certificate | E191658-19880826 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 46 mm |
| Package Level 1 Depth / Length | 49 mm |
| Package Level 1 Height | 58 mm |
| Package Level 1 Gross Weight | 0.175 kg |
| Package Level 1 EAN | 4013614543722 |
| Package Level 2 Units | box 20 piece |
| Package Level 2 Width | 237 mm |
| Package Level 2 Depth / Length | 102 mm |
| Package Level 2 Height | 120 mm |
| Package Level 2 Gross Weight | 3.55 kg |
| Package Level 2 EAN | 4013614543876 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| E-Number (Finland) | 3709426 |