PHOENIX CONTACT MCR-SL-CUC-100-U MCR-SL-CUC-100-U 2308108 PHOENIX CONTACT Universal current transducer View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MCR-SL-CUC-100-U 2308108 PHOENIX CONTACT Universal current transducer

MCR-SL-CUC-100-U

2308108

PHOENIX CONTACT

1 Pcs.

Universal current transducer Universal current converter for the measurement of direct, alternating and distorted currents, 0 input current ... 100 A, 0 output ... 10 V

Automation > Current value transformer
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2308108
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 240 (C-5-2017)
GTIN4046356569736
Weight per Piece (excluding packing)260.000 g
Custom tariff number90303330
Country of originCN (China)

Dimensions

Width90 mm
Height33.8 mm
Depth85 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Input data

Input current range0 A ... 100 A
Overload capacity6 x IIN
Frequency measuring range20 Hz ... 6000 Hz (0 Hz)
Connection methodCable design: 32 mm diameter

Output data

Output nameVoltage output
Voltage output signal0 V ... 10 V
Load/output load voltage output≥ 10 kΩ

Switching output

Output nameNo switching output

Power supply

Nominal supply voltage24 V DC
Supply voltage range20 V DC ... 30 V DC
Max. current consumption30 mA

Connection data

Conductor cross section solid min.0.25 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length10 mm

General

Maximum transmission error
Temperature coefficient, typical0.02 %/K (0 ... 60 °C)
0.04 %/K (-40 °C ... 65 °C)
Linearity error
Step response (10-90%)150 ms
Overvoltage categoryIII
Degree of pollution2
Rated insulation voltage300 V AC
Colorgreen
Housing materialFrianyl B63 V0 GV30
ConformanceCE-compliant
UL, USA/CanadaUL/C-UL listed UL 508

Standards and Regulations

ConformanceCE-compliant
UL, USA/CanadaUL/C-UL listed UL 508

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


ETIM for 2308108 Sensors (EC002475)
Feature Name Feature Value
Initial value measuring range current (EF008198) 0 A
End value measuring range current (EF008266) 100 A
Type of analogy output (EF003958) 0-10 V
Integrated configuration function (EF003064) No
With switching output (EF005225) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.