PHOENIX CONTACT CB TM1 6A F1 P CB TM1 6A F1 P 2800863 PHOENIX CONTACT Thermomagnetic device circuit breaker View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CB TM1 6A F1 P 2800863 PHOENIX CONTACT Thermomagnetic device circuit breaker

CB TM1 6A F1 P

2800863

PHOENIX CONTACT

1 Pcs.

Thermomagnetic device circuit breaker Interrupt. protec. thermomagnetic, 1 pole, caract curve. activ. F1 (fast), 1 inverted contact, connector for base element. Thermomagnetic device circuit breaker, 1-pos., tripping characteristic F1 (fast-blow), 1 changeover contact, plug for base element.

Automation > Device circuit breaker
Over Current Protection

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
GeneralWhen mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly.

Product properties
Product typeThermomagnetic device circuit breakers
Product familyCB TM
TypeMale
Number of positions1
No. of channels1
Data management status
Article revision06
Insulation characteristics
Degree of pollution2

Electrical properties
Fuse typeAutomatic device
General
Rated voltage50 V DC (IEC 60934)
50 V DC (UL 1077)
50 V DC (UL 508 - with plug-in base)
Rated insulation voltage Ui277 V AC (UL 1077)
250 V AC (IEC 60934)
Rated current IN6 A (IEC 60934)
inductive load according to UL 1077
6 A DC (low-induction load according to UL 1077)
6 A DC (inductive load according to UL 508 - with plug-in base)
6 A DC (low-induction load according to UL 508 - with plug-in base)
Rated surge voltage2.5 kV (Increased insulation in actuation area)
Insulation resistance Riso> 100 MΩ (500 V DC)
Auxiliary circuit277 V AC / 0.5 A (Low-induction)
277 V AC / 1 A (Low-induction, maximum of 2000 cycles)
50 V DC / 1 A (Low-induction)
Type of actuationS type
Tripping methodTM (thermomagnetic)
Tripping levelTrip-free mechanism (positive)
Device resistance50 mΩ
Switch-on delaytyp. 2 ms
Required backup fuse24 A (I > Icn)
Rated short-circuit switching capacity Icn600 A (50 V DC)
Short-circuit switching capacity1000 A AC (277 V AC)
1000 A DC (50 V DC)
Dielectric strength3000 V AC (Actuation area)
1500 V AC (Main to auxiliary circuit)
1500 V AC (Open main circuit)
1000 V AC (Open auxiliary circuit)
Switching cycles, max.6000 (at 1 x In)
FuseF1 (fast blow)
Power dissipation1.8 W (in nominal operation per channel)
Voltage drop0.29 V (at 1 x In)
Auxiliary contact
Minimum operating voltage UminDC10 V
Maximum operating voltage UmaxDC240 V
Maximum operating voltage Umax.AC240 V
Minimum operating current Imin10 mA
Max. operating current Imax1 A

Connection data
Connection methodpluggable
Connection methodpluggable

Dimensions
Dimensional drawingsdiglxmoln.jpg
Width12.3 mm
Height45 mm
Depth52 mm
Complete module width12.3 mm
Complete module height90 mm
Complete module depth77.3 mm

Material specifications
Colorgray (RAL 7042)
black (RAL 9005)
Flammability rating according to UL 94V-0
Insulating material groupII

Mechanical properties
Mechanical data
Open side panelNo

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP30 (Actuation area)
Ambient temperature (operation)-30 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Humidity test240 h, 95 % RH, 40 °C
Shock (operation)15g (IEC 60068-2-27, Test Ea)
Vibration (operation)5g (IEC 60068-2-6, Test Fc)

Approvals
UL approval
IdentificationUL Listed UL 508
UL/C-UL Recognized UL 1077
CSA
IdentificationCSA CAN/CSA-C22.2 No. 235-04
Shipbuilding approval
IdentificationDNV GL

Standards and regulations
Standards/specificationsEN 60934

Mounting
Mounting typeon base element

ETIM for 2800863 Circuit breakers and fuses (EC003538)
Feature Name Feature Value
Inflammability class of insulation material according to UL94 (EF002521) Other
Number of poles (EF001391) 1
Construction type (EF000767) Plug
Width (EF000008) 12.3 mm
Height (EF000040) 45 mm
Depth (EF000049) 52 mm
Mounting method (EF000003) Other
Operating voltage (EF000111) 50 V
Nominal current (EF000001) 6 A
Active current limitation x IN (EF011922) 0
Fuse type (EF011923) Other
With remote signalling contact (EF000422) No
Ambient temperature during operating (EF007515) -30 °C

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.