PHOENIX CONTACT UKK 5-HESILED 24 (6,3X32) UKK 5-HESILED 24 (6,3X32) 0711632 PHOENIX CONTACT Fuse modular terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details

UKK 5-HESILED 24 (6,3X32) 0711632 PHOENIX CONTACT Fuse modular terminal block

UKK 5-HESILED 24 (6,3X32)

0711632

PHOENIX CONTACT

50 Pcs.

Fuse modular terminal block Fuse terminal block, fuse type: Glass/ceramic/..., fuse type: G/6.3 x 32, nominal voltage: 400 V, nominal current: 32 A, connection type: Screw connection, Sizing cross-section: 1.5 mm², cross-section: 0.2 mm²- 4 mm², Sizing cross-section: 1.5 mm², mounting class: NS 35/7.5, NS 35/15, NS 32, color: black Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 6,3 x 32, nom. voltage: 400 V, nominal current: 32 A, connection method: Screw connection, Rated cross section: 1.5 mm2, cross section:  0.2 mm2- 4 mm2, Rated cross section: 1.5 mm2, mounting type: NS 35/7,5, NS 35/15, NS 32, color: black

Automation > Fuse terminal block
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Product properties
Product typeFuse terminal block
Number of connections4
Number of rows2
Data management status
Article revision09
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Fuse typeGlass / ceramics / ...
Rated surge voltage6 kV
Maximum power dissipation for nominal condition1.02 W
FuseG / 6,3 x 32
Maximum power dissipationmax. 2.5 W (with single arrangement of the fuse terminal block in the event of overload)
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit)
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)

Connection data
Number of connections per level2
Nominal cross section4 mm²
Level 1 above 1 below 1
Screw threadM3
Tightening torque0.5 ... 0.8 Nm
Stripping length8 mm
Internal cylindrical gageA4
Connection in acc. with standardIEC 60947-7-3
Conductor cross section rigid0.2 mm² ... 4 mm²
Cross section AWG24 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.2 mm² ... 4 mm²
Conductor cross section, flexible [AWG]24 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.25 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.25 mm² ... 4 mm²
2 conductors with same cross section, solid0.2 mm² ... 1.5 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 1.5 mm²
Nominal current32 A
Maximum load current32 A
Nominal voltage400 V
Nominal cross section1.5 mm²
Nominal current10 A
Maximum load current10 A
Nominal voltage400 V
Nominal cross section1.5 mm²

Dimensions
Width8.2 mm
Height86.5 mm
Depth on NS 3284 mm
Depth on NS 35/7,579 mm
Depth on NS 35/1586.5 mm

Material specifications
Colorblack (RAL 9005)
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Mechanical properties
Mechanical data
Open side panelNo

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Standards and regulations
Connection in acc. with standardIEC 60947-7-3

Mounting
Mounting typeNS 35/7,5
NS 35/15
NS 32

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.