PHOENIX CONTACT PSR-SPP-24UC/URM/5X1/1X2 PSR-SPP- 24UC/URM/5X1/1X2 2981965 PHOENIX CONTACT Coupling relay View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSR-SPP- 24UC/URM/5X1/1X2 2981965 PHOENIX CONTACT Coupling relay

PSR-SPP-24UC/URM/5X1/1X2

2981965

PHOENIX CONTACT

1 Pcs.

Coupling relay Safe coupling relay with forced-conduction contacts, 5 NO contacts, 1 NC contacts, width: 22.5 mm, plug-in push-in terminal block

Automation > Device for monitoring of safety-related circuits
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2981965
Packing unit1 pc
Catalog pagePage 278 (C-6-2017)
GTIN4046356343572
Weight per Piece (excluding packing)173.000 g
Custom tariff number85364900
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width22.5 mm
Height114.5 mm
Depth112 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Maximum altitudemax. 2000 m (Above sea level)

Input data

Rated control circuit supply voltage US24 V AC/DC -15 % / +10 %
Rated control supply current IStyp. 47 mA
Power consumption at UStyp. 1.2 W
Inrush currenttyp. 350 mA DC (Δt s)
typ. 350 mA AC (Δt = 2 ms at Us)
Typ. starting time with Ustyp. 20 ms (when controlled via A1)
Typical release timetyp. 20 ms (when controlled via A1)
Recovery time< 500 ms
Operating voltage display1 x green LED
Protective circuitSurge protection Varistor
Maximum switching frequency0.5 Hz

Output data

Contact type5 enabling current paths
1 signaling current path
Contact materialAgSnO2
Maximum switching voltage230 V AC/DC (Observe the load curve)
Minimum switching voltage5 V AC/DC
Limiting continuous current6 A (N/O contact)
6 A (N/C contact)
Maximum inrush current6 A
Inrush current, minimum10 mA
Sq. Total current72 A2
Interrupting rating (ohmic load) max.144 W (N/O contact, 24 V DC, τ = 0 ms)
288 W (N/O contact, 48 V DC, τ = 0 ms)
240 W (N/O contact, 60 V DC, τ = 0 ms)
110 W (N/O contact, 110 V DC, τ = 0 ms)
88 W (N/O contact, 220 V DC, τ = 0 ms)
1380 VA (N/O contact, 230 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load)42 W (N/O contact, 24 V DC, τ = 40 ms)
42 W (N/O contact, 48 V DC, τ = 40 ms)
42 W (N/O contact, 60 V DC, τ = 40 ms)
42 W (N/O contact, 110 V DC, τ = 40 ms)
42 W (N/O contact, 220 V DC, τ = 40 ms)
Switching capacitymin. 50 mW
Mechanical service life10x 106cycles
Switching capacity (360/h cycles)4 A (24 V (DC13))
4 A (250 V (AC15))
Switching capacity according to IEC 60947-5-13 A (24 V (DC13))
3 A (250 V (AC15))
Output fuse10 A gL/gG (N/O contact)
4 A gL/gG (N/O contact, for low-demand applications)
6 A gL/gG (N/C contact)

General

Relay typeElectromechanical relay with forcibly guided contacts in accordance with EN 50205
Nominal operating mode100% operating factor
Net weight173 g
Mounting positionvertical or horizontal
Mounting typeDIN rail mounting
Degree of protectionIP20
IP54
Min. degree of protection of inst. locationIP54
Housing materialPBT
Housing coloryellow

Connection data

Connection methodSpring-cage connection
pluggableYes
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Safety-related characteristic data

Stop category0
DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)1
DesignationIEC 61508 - Low demand
Safety Integrity Level (SIL)1
DesignationEN ISO 13849
Performance level (PL)c
Category1
Safety Integrity Level Claim Limit (SIL CL)1

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Rated insulation voltage250 V
250 V
Rated surge voltage/insulation4 kV / basic isolation (safe isolation, reinforced isolation and 6 kV between A1/A2, 53/54, 71/72 and 13/14, 23/24, 33/34, 43/44.)
Degree of pollution2
Overvoltage categoryIII
Shock15g (In the event of stress caused by shock, contact reactions are possible for up to 2 ms.)
Vibration (operation)10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.)
ConformanceCE-compliant

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 2981965 Relays (EC001449)
Feature Name Feature Value
Model (EF000010) Basic device
Suitable for rail mounting (EF003972) Yes
With detachable clamps (EF003340) Yes
Type of electric connection (EF003961) Spring clamp connection
Suitable for monitoring of emergency-stop circuits (EF007268) No
Suitable for monitoring of valves (EF007272) No
Suitable for monitoring of optoelectronic protection equipment (EF007269) No
Suitable for monitoring of tactile sensors (EF007271) No
Suitable for monitoring of magnetic switches (EF007266) No
Suitable for monitoring of proximity switches (EF007267) No
Evaluation inputs (EF008245) Other
With start input (EF003342) No
With muting function (EF004057) No
With feedback circuit (EF003343) No
Release-delay (EF001129) 0.02 s
Number of outputs, safety related, undelayed, with contact (EF003344) 0
Number of outputs, safety related, delayed, with contact (EF003345) 0
Number of outputs, safety related, undelayed, semiconductors (EF003346) 0
Number of outputs, safety related, delayed, semiconductors (EF003347) 0
Number of outputs, signalling function, undelayed, with contact (EF003348) 0
Number of outputs, signalling function, delayed, with contact (EF003349) 0
Number of outputs, signalling function, undelayed, semiconductors (EF003350) 0
Number of outputs, signalling function, delayed, semiconductors (EF003351) 0
Stop category according to IEC 60204 (EF007498) Other
With approval for BG BIA (EF004145) No
With approval according to UL (EF001783) No
Width (EF000008) 22.5 mm
Height (EF000040) 114.5 mm
Depth (EF000049) 112 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.