Installation terminal block Terminal block, nominal voltage: 800 V, nominal current: 125 A, Screw connection, Dimensioning cross-section: 35 mm², cross-section: 0.75 mm² - 35 mm², installation class: NS 35/7.5, NS 35/15, colour: blue Installation terminal block, nom. voltage: 800 V, nominal current: 125 A, Screw connection, Rated cross section: 35 mm2, cross section: 0.75 mm2 - 35 mm2, mounting type: NS 35/7,5, NS 35/15, color: blue

Automation > Multi level installation terminal block
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey3075731
Packing unit50 pc
Catalog pagePage 255 (C-1-2017)
GTIN4046356518048
Weight per Piece (excluding packing)46.390 g
Custom tariff number85369010
Country of originCN (China)

General

Number of levels1
Number of connections2
Potentials1
Nominal cross section35 mm²
Colorblue
Insulating materialPA
Flammability rating according to UL 94V2
Maximum load current125 A (with 35 mm² conductor cross section)
Rated surge voltage8 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition4.06 W
Maximum load current125 A (with 35 mm² conductor cross section)
Nominal current IN125 A
Nominal voltage UN800 V
Open side panelNo
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width15.2 mm
Length55 mm
Height NS 35/7,551 mm
Height NS 35/1558.5 mm

Connection data

NoteTerminal point
Connection methodScrew connection
Screw threadM6
Stripping length16 mm
Tightening torque, min3.2 Nm
Tightening torque max3.7 Nm
Connection in acc. with standardIEC 60947-7-1
Conductor cross section solid min.0.75 mm²
Conductor cross section solid max.35 mm²
Conductor cross section AWG min.18
Conductor cross section AWG max.2
Conductor cross section flexible min.0.75 mm²
Conductor cross section flexible max.35 mm²
Min. AWG conductor cross section, flexible18
Max. AWG conductor cross section, flexible2
Conductor cross section flexible, with ferrule without plastic sleeve min.0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.35 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.75 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.35 mm²
Cross section with insertion bridge, solid max.35 mm²
Cross section with insertion bridge, stranded max.35 mm²
2 conductors with same cross section, solid min.0.75 mm²
2 conductors with same cross section, solid max.10 mm²
2 conductors with same cross section, stranded min.0.75 mm²
2 conductors with same cross section, stranded max.10 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min.0.75 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.6 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min.0.75 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max.10 mm²

Standards and Regulations

Connection in acc. with standardIEC 60947-7-1
Flammability rating according to UL 94V2
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 3075731 Terminal blocks (EC001329)
Feature Name Feature Value
Connectable conductor cross section fine-strand without cable end sleeve (EF007341) 0.75 mm²
Connectable conductor cross section solid-core (EF007337) 0.75 mm²
Connectable conductor cross section multi-wired (EF007343) 0.75 mm²
Rated current In (EF008250) 125 A
Rated voltage (EF000228) 800 V
Type of electrical connection 1 (EF002526) Screw connection
Type of electrical connection 2 (EF002527) Screw connection
Mounting method (EF000003) Other
Material insulation body (EF007543) Other
Inflammability class of insulation material according to UL94 (EF002521) V2
Width (EF000008) 15 mm
Height (EF000040) 54.925 mm
Depth (EF000049) 49.8 mm
Closing plate required (EF002525) No
Basic colour (EF002671) Blue
PE-function (EF002672) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.